Belden Caltrans Inductive Loop Detector Type C Lead-In IMSA Spec 50-2 Cable

Belden Caltrans Inductive Loop Detector Type C Lead-In IMSA Spec 50-2 Cable

Select gauge from drop-down menu for prices:

Belden Caltrans Inductive Loop Detector Type C Lead-In IMSA Spec 50-2 Cable
Belden CALTRANS Inductive Loop Detector Type C Lead-In IMSA Spec 50-2 Cable

Belden offers a wide range of products for various municipal transportation applications: traffic communication, fire protective signal, data acquisition, inductance loop detection and traffic signal control.

Manufactured in ISO-certified facilities, Belden provides unsurpassed quality and reliability to ensure product consistency for every specification.

Features:
• Outdoor, moisture, and sunlight resistant for wet or dry locations
• Multiple standard conductor, insulation and jacket selections available
• Additional constructions available upon request

Benefits:
• Improved system uptime
• Improved protection against noise and unintended or outside signals
• Robust designs which meet or exceed International Municipal Signal Association (IMSA) specifications

Ground Wire:
• Ground Wire (Y/N): N

Insulation:
• Material: LDPE - Low Density Polyethylene
• Wall Thickness (mm): 0.762

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 19x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: LDPE - Low Density Polyethylene
• Nom. Wall Thickness (mm): 0.762

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Bulk Cable Weight: 58.040 Kg/Km
• Max. Recommended Pulling Tension: 311.374 N
• Min. Bend Radius/Minor Axis: 78.740 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• IMSA Specification: 50-2, CALTRANS Type C

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 13.7802

Suitability:
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal dia. (mm)
belden cable
part number
Action
16 2 7.849 603133 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question