Belden 8 AWG CSA Control 600V and 1000V TECK 90 7x16 Armored Unshielded Cable

Belden 8 AWG CSA Control 600V and 1000V TECK 90 7x16 Armored Unshielded Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 10
• Ground Wire Stranding: 7x18
• Conductor Material: BC - Bare Copper
• Insulation Material: Uninsulated

Insulation:
• Material: XLP - Cross Linked Polyolefin
• Wall Thickness (mm): 1.143

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.600
• Nom. Dia. (mm): 15.088
• Outer Jacket over Armor (y/n): Y

Outer Jacket Over Armor:
• OJ Over Armor Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 23.241

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.819

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 407 lbs/1000 ft.
• Max. Recommended Pulling Tension: 200 lbs.
• Min. Bend Radius/Minor Axis: 10.900 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #131; Hazardous Location; C22.2 #0.3 Clause 4.31 Low Acid Gas, C22.2 #174 HL
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 0.640
• Max. Recommended Current: 44 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors outer shield -
material
belden cable
part number
Action
8 2 unshielded C5583 Request A Quote
8 3 unshielded C5581 Request A Quote
8 4 unshielded C5582 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question