Product Details
Conductor: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.
Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580.
Shield: An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.
Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.
Applications
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed).
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version.
Approvals
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• CSA 22.2 No. 230 as Type TC (#4/0 AWG and larger)
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR
Features/Ratings
• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore
Number of Conductors Size |
Number of Conductors |
Cable Weight (approximate) |
Prysmian and Draka Cable Part Number |
Action |
kg/km | ||||
20 | 3 | 95 | T26491 | Request A Quote |
20 | 4 | 120 | T26492 | Request A Quote |
20 | 5 | 135 | T26493 | Request A Quote |
20 | 6 | 155 | T26494 | Request A Quote |
18 | 3 | 120 | - | Request A Quote |
18 | 4 | 140 | T26496 | Request A Quote |
18 | 5 | 170 | T26497 | Request A Quote |
18 | 6 | 195 | T26498 | Request A Quote |
18 | 25 | 590 | - | Request A Quote |
16 | 3 | 135 | T30645 | Request A Quote |
16 | 4 | 165 | T26500 | Request A Quote |
16 | 5 | 195 | T26501 | Request A Quote |
16 | 6 | 225 | T26502 | Request A Quote |
16 | 12 | 380 | T27052 | Request A Quote |