Skip to product information
1 of 1

Belden 14 AWG Triads Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable

Belden 14 AWG Triads Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable

SKU: SKU:  

Select a gauge:
  • Belden 14 AWG Triads Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable
Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Sold out
Shipping calculated at checkout.
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
View full details
Product Information
Belden 14 AWG Triads Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Outer Shield Drain Wire AWG:
• AWG: 16
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.176
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 97 lbs/1000 ft.
• Max. Recommended Pulling Tension: 200 lbs.
• Min. Bend Radius/Minor Axis: 3.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 57
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/ft): 102
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.3
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.4
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 10 Amps/conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads overall cable-
nominal dia. (mm)
belden cable
part number
Action
14 1 9.169 3081A Request A Quote
Reviews