Belden C5611 3 AWG 3 Conductors 1000V TECK 90 Armored Unshielded Cable
Select gauge from drop-down menu for prices:
Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.
Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.
Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance
Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 6
• Ground Wire Stranding: 7x14
• Conductor Material: BC - Bare Copper
• Ground Wire Insulation Material: Uninsulated
Insulation:
• Material: XLPE - Cross Linked Polyethylene
• Wall Thickness (mm): 1.524
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 2.108
• Nom. Dia. (mm): 24.638
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 33.680
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 1.23
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 1675.713 Kg/Km
• Max. Recommended Pulling Tension: 889.640 N
• Min. Bend Radius/Minor Axis: 401.320 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #131; Hazardous Location; C22.2 #0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 0.6562
• Max. Recommended Current: 104 Amps/Conductor @ 25°C
Flame Test:
• CSA Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
3 | 3 | 33.020 | C5611 | Request A Quote |