Service Wire 10,12,14 AWG Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable
Select gauge from drop-down menu for prices:
- Service Wire 14 AWG 2 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/2
- Service Wire 14 AWG 3 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/3
- Service Wire 14 AWG 4 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/4
- Service Wire 14 AWG 5 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/5
- Service Wire 14 AWG 7 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/7
- Service Wire 14 AWG 9 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/9
- Service Wire 14 AWG 12 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/12
- Service Wire 14 AWG 19 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/19
- Service Wire 14 AWG 37 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH14/37
- Service Wire 12 AWG 2 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/2
- Service Wire 12 AWG 3 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/3
- Service Wire 12 AWG 4 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/4
- Service Wire 12 AWG 5 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/5
- Service Wire 12 AWG 7 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/7
- Service Wire 12 AWG 9 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/9
- Service Wire 12 AWG 12 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/12
- Service Wire 12 AWG 19 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/19
- Service Wire 12 AWG 37 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH12/37
- Service Wire 10 AWG 2 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/2
- Service Wire 10 AWG 3 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/3
- Service Wire 10 AWG 4 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/4
- Service Wire 10 AWG 5 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/5
- Service Wire 10 AWG 7 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/7
- Service Wire 10 AWG 9 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/9
- Service Wire 10 AWG 12 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/12
- Service Wire 10 AWG 19 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/19
- Service Wire 10 AWG 37 Conductors Jacket MC XHHW-2 Zero Halogen Limited Smoke 600V Copper Cable AANH10/37
Description:
This halogen free limited smoke copper cable is tough service cable. This cable has different gauge sizes ranging from 10 to 12 to 14 American wire Gauge, AWG. The outstanding feature of this cable is its MC XHHW-2 jacket which has been tested and certified for zero halogen and with limited smoke. This jacket is flame retardant and with excellent heat resistance. The cable is fitted with insulated copper conductors with proper jacketing to make sure it survives the underground environment on direct burial.
Applications:
Halogen free limited smoke copper cable shows excellent performance in hazardous, heavy duty applications. It has a tough, sturdy and robust jacket that shows very high resistance to heat and moisture, it can therefore be directly buried in underground cabling.
Its wide temperature range of -40°C to 90°C in both wet and dry locations makes it fit for marshy and punishing applications. This cable can be used in exposed cabling above the ground because of its good resistance to UV and weather. It can also serve in duties that require ampacity of up to 600V
Conductor:
• Fully Stranded Copper conductor
Insulation:
• Type MC XHHW-2 crosslinked polyethylene material.
Jacket:
• Type MC XHHW-2 jacket or EnviroPlus
• Zero lead jacket
• Halogen free material
• Has very Limited smoke
Features:
• Temperature rating of 90°C; wet and dry locations
• -40°C Temperature rating for cold locations
• Excellent sunlight resistance
• Suitable for direct burial
• Two-firewall
• Halogen free jacket
Standards:
• UL 15581
• UL 1685
• UL 1569
• IEEE 383 Flame test, 70000 BTU
• IEEE 1202
• NEMA WC-70
• ICEA S-95-658
• CSA FT-4
• RoHS compliant