General Cable EmPowr® 35 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

General Cable EmPowr® 35 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

Select gauge from drop-down menu for prices:

General Cable EmPowr® 35 kV Longitudinally Applied Corrugated Tape LLDPE Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

Product Details

Complete Cable: Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Corrugated copper tape and an extruded black jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97-682 and AEIC CS8 as applicable for Ethylene Propylene Rubber (EPR) insulated shielded power cable.

Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum.

Conductor Shield: Extruded semi-conducting thermosetting polymeric stress control layer.

Insulation: Extruded Ethylene Propylene Rubber (EPR) Class II and III.

Insulation Shield: Extruded semi-conducting thermosetting layer, clean and free stripping from insulation.

Longitudinally Applied Corrugated Tape: Copper, 8 or 10 mil thick Longitudinally Applied Corrugated Tape (LACT) with a minimum 375 mil overlap.

Jacket: Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE).

Features and Benefits:
• Even distribution of fault current and better heat dissipation
• Allows expansion/contraction of cable core
• Improved bending characteristics versus helical copper tape shield
• Triple-extruded for clean interfaces
• Class 10,000 environment utilized for cable core material handling
• Flexibility for easy handling
• Excellent moisture resistance
• Deformation-resistant
• High dielectric strength
• Low dielectric loss
• Excellent resistance to water treeing
• Clean-stripping insulation shield without the use of a release agent
• Sunlight-resistant

Temperature Rating:
• Normal - 105°C
• Emergency* - 140°C
• Short Circuit - 250°C

Applications: EmPowr® Fill cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried.

Options:
• Copper conductors
• EmPowr® Fill LF Lead-Free EAM
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610
• BIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core/LACT
• TRIFILL® tested to ICEA T-34-664 1. blocked conductor 2. blocked cable core/LACT 3. sealed overlap and blocked LACT/jacket
• Sealed LACT overlap
• Dry nitrogen cure
• True Triple Extrusion
• Red stripes on jacket
• Semi-conducting thermoplastic jacket
• 3 X 1/C triplex or parallel
• Type MV-90 UL 1072
• UL Listed

compressed conductor diameter (1) inches approx. weight (1) lb/1000 ft ampacity (2) Action
al awg or kcmil insulation max. total in duct
345 mils nominal epr insulation – 35 kv 100% insulation level
250 1.350 1305 295 Request a Quote
250 1.350 1352 295 Request a Quote
350 1.455 1594 355 Request a Quote
350 1.455 1640 355 Request a Quote
500 1.580 1858 430 Request a Quote
500 1.580 1911 430 Request a Quote
750 1.770 2294 550 Request a Quote
750 1.770 2346 550 Request a Quote
1000 1.920 2668 625 Request a Quote
1000 1.920 2732 625 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question