Belden 18 AWG Pairs Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

Belden 18 AWG Pairs Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

Product Details

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.2192
• Outer Jacket Ripcord: Yes

Overall Cabling Lay Length and Direction:
• Length (in.): 4.0

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 77 lbs/1000 ft.
• Max. Recommended Pulling Tension: 140 lbs.
• Min. Bend Radius/Minor Axis: 3.800 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532 (WC57), S-61-402

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.91
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.460 Ohm/1000 ft
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part number
Action
18 2 9.601 1048A Request A Quote
18 4 12.522 1049A Request A Quote
18 8 17.145 1050A Request A Quote
18 12 19.939 1051A Request A Quote
18 16 22.809 1052A Request A Quote
18 24 27.686 1053A Request A Quote
18 36 32.995 1054A Request A Quote
18 50 38.786 1038A Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question