5kV-8kV Type MV-105 - 115 Mils EPR w. PVC Jacket

5kV-8kV Type MV-105 - 115 Mils EPR w. PVC Jacket

Product Information
Length
Price (Per FT.)
Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action
Length
/FT
Price (Per FT.)

$5.86

Action
Length
/FT
Price (Per FT.)

$8.40

Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action
Length
/FT
Price (Per FT.)

$11.47

Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action
Length
/FT
Price (Per FT.)

$18.35

Action
Length
/FT
Price (Per FT.)

$17.63

Action
Length
/FT
Price (Per FT.)
Call 516-472-0650 for pricing
Action

Product Details

The 5kV-8kV Type MV-105 - 115 Mils EPR with PVC Jacket cable’s conductive component of this cable is a concentric compact stranded class B copper conductor.  The class B copper in this cable is annealed to make the conductor softer and more malleable.  The conductor is covered by triple single head extruded conductor shield.  The conductor shield is then insulated with a dry cured ethylene propylene insulation that bears an easy strippable bare copper insulation shield.  The bare copper insulation shield is made of 5 mils annealed copper with an overlap of 25%.  A black, surface printed polyvinyl chloride (PVC) jacket serves as the external layer of the cable.  The exterior jacket is flame-retardant and moisture and sunlight resistant. 

5kV-8kV Type MV-105 - 115 Mils EPR with PVC Jacket cable is used in distribution, main feeder and branch circuits for commercial, industrial, and electric utility installations.  The cable can be installed in aerial applications, direct burial, conduit open tray, and underground duct installations.  When installed in accordance with NEC regulations, the cable is safe for use in wet or dry locations.  For direct burial applications, ensure the cable is installed in a system with a ground conductor that is in close proximity with NEC 250.4(A)(5).  Under normal operating conditions, this cable is able to function at temperatures up to 105°C.  At emergency operating conditions, the cable can tolerate temperatures up to 140°C.  In short circuit situations, the cable has a temperature rating of 250°C.  

 

Size
(AWG or KCMIL)
Number of Conduc
-tors in Cable
Jacket Thick
-ness (mils)
Nominal Insul
-ation Thick
-ness (mm)
Size AWG
Stranding
Diameter Weight Per 1000ft Total (Lbs.) Ampacity
Allow
-able Amp
-acity in Ducts (Amps)
Over Insul
-ation (Inches)
Over Insul
-ation Shield (Inches)
Comp
-lete Cable (O.D.) (Inches)
1/C in Cable Tray (Amps)
1/C Cond
-uit in Air (Amps)
2 Gauge 5-8kV Power Cable 115 Mils 1 55 115 2 7 0.550 0.640 0.840 510 n/a 165 165
1 Gauge 5-8kV Power Cable 115 Mils 1 55 115 1 19 0.590 0.680 0.880 620 n/a 190 185
1/0 5-8kV Power Cable 115 Mils 1 55 115 1/0 19 0.650 0.720 0.920 670 290 215 215
2/0 5-8kV Power Cable 115 Mils 1 70 115 2/0 19 0.690 0.770 0.980 790 335 255 245
3/0 5-8kV Power Cable 115 Mils 1 70 115 3/0 19 0.740 0.820 1.030 920 385 290 275
4/0 5-8kV Power Cable 115 Mils 1 70 115 4/0 19 0.800 0.870 1.080 1080 445 330 315
250MCM 5-8kV Power Cable 115 Mils 1 70 115 250 37 0.860 0.930 1.140 1230 495 365 345
350MCM 5-8kV Power Cable 115 Mils 1 70 115 350 37 0.960 1.030 1.240 1580 610 440 415
500MCM 5-8kV Power Cable 115 Mils 1 70 115 500 37 1.080 1.170 1.370 2090 765 535 500
750MCM 5-8kV Power Cable 115 Mils 1 70 115 750 61 1.270 1.360 1.560 2950 990 655 610
1000MCM 5-8kV Power Cable 115 Mils 1 70 115 1000 61 1.420 1.510 1.710 3910 1185 755 690