General Cable Type RA90 XLPE 1/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®

General Cable Type RA90 XLPE 1/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®

Select gauge from drop-down menu for prices:

General Cable Type RA90 XLPE 1/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
Type RA90 XLPE 1/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW

Conductor:
• Bare annealed copper per ASTM B3 
• Sizes 10 AWG and smaller are Class B compressed stranding per ASTM B8 
• Sizes 8 AWG and larger are compact stranding per ASTM B496

Insulation: 
• Cross-linked Polyethylene (XLPE) insulation rated 1000 Volts, RW90 per CSA C22.2 No. 38 
• Sizes 2 AWG and smaller utilize a single color insulation: black, red and blue 
• Sizes 1 AWG and larger utilize black insulation with printed number/color, 1-black, 2-red, 3-blue

Bonding/Grounding Conductors: 
• Class B stranded bare annealed copper per ASTM B3 and B8 
• Three (3) symmetrical grounding wires are sized in accordance with CEC Table 16

Cable Assembly: 
• Three symmetrical grounding wires are cabled within the interstices of the phase conductors 
• Non-hygroscopic fillers when required 
• A binder tape is applied over the cabled core

CCW Armor:  Impervious, continuously welded and corrugated aluminum alloy sheath per C22.2 No. 123

Jacket: 
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black 
• Meets CSA Low Gas Emission requirements, AG14

Applications: 
• Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for   use with AC motors controlled by pulse-width modulated inverters in VFD applications 
• CCW armored cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods 
• For use in industrial and commercial installations including hazardous locations in accordance with the CEC 
• Can be installed in wet or dry locations, indoors or outdoors, in cable trays, in a raceway, or direct buried in accordance with the CEC

Features: 
• 90°C, 1000 V wet or dry XLPE insulation and three (3) symmetrical grounding wires, recommended for use with pulse-width modulated AC    drives 
• XLPE insulation has a dielectric constant less than 3.0 to withstand momentary voltage spikes common with VFD applications  
• CCW armor provides an impervious barrier to moisture, gas and liquids 
• CCW armor provides EMI shielding performance 
• Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems 
• Meets cold impact at -40°C 
• 90°C continuous operating temperature, wet or dry 
• 130°C emergency rating 
• 250°C short circuit rating

Specifications:

Design Adherence: 
• CSA C22.2 No. 38 Thermoset- Insulated Wires and Cables 
• CSA C22.2 No. 123 Metal Sheathed Cables 
• CSA C22.2 No. 174 Cables and Cable Glands for Use in Hazardous Locations

Flame Tests: 
• CSA FT4 
• ICEA T-29-520 (210,000 BTU/hr) 
• IEEE 383 (70,000 BTU/hr) 
• IEEE 1202 (70,000 BTU/hr)

Compliances: 
• CSA Certified Type RA90, XLPE, HL, SR, FT4, AG14 and -40°C, CSA File # 7319 
• RoHS Compliant

technical specification:
cond. size (awg/kcmil)
1/0 (19/w) (53.5 mm²)
no. of cond. 3
insulation thickness (mils) 80
insulation thickness (mm) 2.03
bare ground cond. (awg) 3 x #10
nominal core o.d. (inches) 1.09
nominal core o.d. (mm) 27.8
nominal armor o.d. (inches) 1.42
nominal armor o.d. (mm) 36.0
jacket thickness (mils) 50
jacket thickness (mm) 1.27
nominal overall o.d.(inches)
1.52
nominal overall o.d. (mm) 38.6
approximate netweight (lbs/1000 ft) 1,623
approximate netweight (kg/1000 m) 2,415
min. bend radius ¹(inches) 18.2
min. bend radius ¹(mm) 462
90°c ampacity @ 30°c ambient² 170
catalog number 9675.11003310