HF22 Indoor/Outdoor Central Tube Single Jacket Riser Cable Type OFNR, CSA FT-4
Select gauge from drop-down menu for prices:
- HF22 INDOOR/OUTDOOR CENTRAL TUBE SINGLE JACKET RISER CABLE Type OFNR, CSA FT-4 - 2 Fiber Count
- HF22 INDOOR/OUTDOOR CENTRAL TUBE SINGLE JACKET RISER CABLE Type OFNR, CSA FT-4 - 4 Fiber Count
- HF22 INDOOR/OUTDOOR CENTRAL TUBE SINGLE JACKET RISER CABLE Type OFNR, CSA FT-4 - 6 Fiber Count
- HF22 INDOOR/OUTDOOR CENTRAL TUBE SINGLE JACKET RISER CABLE Type OFNR, CSA FT-4 - 8 Fiber Count
- HF22 INDOOR/OUTDOOR CENTRAL TUBE SINGLE JACKET RISER CABLE Type OFNR, CSA FT-4 - 12 Fiber Count
Product Details
Description
This nonconductive optical fiber riser cable comes with the option of 2-12 fibers with a dry central tube. The central tube includes an absorbent polymer that soaks up any interior moisture. The cable is designed for flexibility and is incredibly easy to install. The dry loose tube construction of the cable also makes for easy termination when necessary. Aramid fiber yarn serves as the overall strength member of the cable. The assembly is jacketed in a black UB and moisture-resistant coating that composed of flame retardant materials. Sequential markings on the exterior jacket measure footage for reference during installation.
Applications:
This cable is used as a backbone for voice and communication data within a building. The riser cable is intended for vertical runs between floors but it can also be installed in horizontal when installed in compliance with NEC article 770-51(b) and 770-53(b). The cable can be installed in ducts or conduits, or can be aerially lashed. The cable is capable of functioning at temperatures between -20°C and 70°C. The cable has a maximum crush resistance of 150 lbs and a maximum vertical rise of 1,200 feet. (366m).
Specifications:
• The HF22 model cable passes the CSA FT-4 flame test. This test requires the product to be able to retard flames up to 70,000 BTU.
• The product is Listed Type OFNR in accordance with specifications set forth by ETL and c(ETL).
• Insulated Cable Engineers Association (ICEA) standard S-104-696 approves this cable for use in outdoor plants.
Construction:
Fibers:
• This cable comes with the option of 2-12 fibers plus a dry central tube with an absorbent polymer. The fibers are color coded per TIA/EIA 598B.
Jacket:
• The assembly is jacketed in a black flame resistant coat. The jacket is also resistant to UV rays and moisture.
Catalog Number | Fiber Count | Min. Bend Radius Install Inch |
Min. Bend Radius Long Term Inch |
Action |
222002XL03 | 2 | 6.8 | 3.4 | Request a Quote |
222004XL03 | 4 | 6.8 | 3.4 | Request a Quote |
222006XL03 | 6 | 6.8 | 3.4 | Request a Quote |
222008XL03 | 8 | 6.8 | 3.4 | Request a Quote |
222012XL03 | 12 | 6.8 | 3.4 | Request a Quote |