Belden 2132A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Foundation Fieldbus Cable
- Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable
- Belden 123077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable
- Belden 133077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable
- Belden 3078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable
- Belden 123078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable
- Belden 133078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable
- Belden 3076F Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 123076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable
- Belden 133076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable
- Belden 183076F Cable 18 AWG 1 Pair Foundation Fieldbus/ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Continuous Armor Cable
- Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable
- Belden 2100A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S3076NH Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1327A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2101A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1327NH Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1328A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2102A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1328NH Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1329A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2103A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1329NH Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1330A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2104A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1330NH Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1331A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2105A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1331NH Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1332A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2106A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1332NH Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1333A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2107A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1333NH Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1359A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2108A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden 1360A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2109A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1361A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2110A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1362A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2111A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1363A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2112A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1364A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2113A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1365A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2114A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1366A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2115A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1367A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2116A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 2117A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable
- Belden 1337A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2118A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2119A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket 600V Cable
- Belden 1339A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus PA DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2120A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket 600V Cable
- Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1341A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2122A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1342A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2123A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1343A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2124A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1344A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2125A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden 2126A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2127A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2128A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2129A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2130A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2131A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2133A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2134A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2135A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
Description:
• 16 pair, 16 AWG, Stranded (7x24) Tinned Copper, 600V, Individually Foil Shielded Pairs, Overall Beldfoil Sheild, Tinned Copper Drain Wires, XLP Insulation, Sunlight- and oil-resistant TPE jacket.
Insulation:
• Material: XLP - Cross-Linked Polyolefin
Inner Shield:
• Type: Tape
• Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Conductor Material: TC - Tinned Copper
Outer Shield Drain Wire AWG:
• AWG: 16
• Stranding: 7x24
• Conductor Material: TC - Tinned Copper
Outer Jacket:
• Material: TPE - Thermoplastic Elastomer
• Outer Jacket Ripcord: Yes
Mechanical Characteristics (Overall):
• Operating Temperature Range: -25°C Cold Impact, -40°C To +90°C, -55°C Cold Bend
• UL Temperature Rating: 90°C Wet/Dry
• Installation Temperature Rating: -25°C
• Bulk Cable Weight: 847 lbs/1000 ft.
• Max. Recommended Pulling Tension: 1536 lbs.
• Min. Bend Radius/Minor Axis: 13.250 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: TC-ER
• CSA Specification: AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: IEC 61158-2 (ISA/SP-50) Type A
Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100
• Nom. Inductance (μH/ft): 0.220
• Nom. Capacitance Conductor to Conductor (pF/ft): 22.000
• Maximum Capacitance Unbalance (pF/ft): 1.2
• Nominal Velocity of Propagation: VP (%): 64.000
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 4.200
• Max. Operating Voltage - UL: 600 V RMS
• Max. Operating Voltage - Other: 600V RMS (CSA CIC type TC)
• Max. Recommended Current: 7.2 Amps/Conductor
Flame Test:
• UL Flame Test: UL1581 Vertical Tray
• CSA Flame Test: FT4
• IEC Flame Test: 60332-3-24 (Category C)
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes
Plenum/Non-Plenum:
• Plenum(Y/N): No
technical specification: | |
awg | 16 |
# pairs | 16 |
stranding | 7x24 |
no. of conductors | 32 |
conductor material | tinned copper |
diameter (in.) | - |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable - nominal diameter (in.) | 1.321 |
belden cable part number | 2132A |