Belden 29530X Cable 2/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
Select gauge from drop-down menu for prices:
- Belden Cable Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29528X Cable 1 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29529X Cable 1/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29531X Cable 3/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29532X Cable 4/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
Classic Symmetrical Designs Features:
• Available with high-strand conductors in
large AWG sizes
• Design features a copper tape shield
with segmented ground
• Smaller OD than the Classic Designs
with Foil/Braid
• Industrial-grade PVC jackets provide sunlight-
and oil-resistance; Haloarrest jackets are
halogen-free and provide sunlight-resistance in
LSZH versions
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 100% ground three conductor
• Shielding: Dual Copper Tape
• Grounding: Bare 3x Segmented
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Tinned Copper
• Rating: 1000V UL Flexible Motor Supply
• 600V UL 1277 Type TC-ER
• CSA FT4
• IEEE 1202
• UL Oil Res 2 & IEC 60811-2-1
Hydrocarbon resistant
• UL 1685 Vertical Tray Flame Test
• XHHW-2, rated circuit
conductors
• -40° C cold bend, IEC 60332-3-22
Cat A (flame test)
• 90° C Wet/Dry
• Suitable for Class I, II & III, Division
2 hazardous locations
• IEC 60754-1,-2 (acid gas emissions)
• MSHA (pending approval)
• RoHS compliant
• CE approved
• Marine approvals: ABS, DNV, UL
1309 Type, IEEE 45, IEEE1580 Type P
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
technical specification | |
awg | 2/0 |
cond. stranding | 7 x 19 x 20 |
standard lengths ft. | 1000 |
standard lengths m | 304.8 |
standard unit wt. lbs. | 2331 |
standard unit wt. kg | 1057.3 |
nominal od inch | 1.40 |
nominal od mm | 35.56 |
maximum pull tension lbs. | 4200 |
maximum pull tensionn | 18682 |
minimum bend radius inch | 14.0 |
minimum bend radius mm | 355.6 |
belden cable part number | 29530X |