Belden 2139A Cable 24 AWG 25 Pairs Category 5E Indoor/Outdoor OSP and CM-LS 25pr Multi Conductor UnShielded Solid BC FR PO Jacket Cable

Belden 2139A Cable 24 AWG 25 Pairs Category 5E Indoor/Outdoor OSP and CM-LS 25pr Multi Conductor UnShielded Solid BC FR PO Jacket Cable

Select gauge from drop-down menu for prices:

Belden 2139A Cable 24 AWG 25 Pairs Category 5E Indoor/Outdoor OSP and CM-LS 25pr Multi Conductor UnShielded Solid BC FR PO Jacket Cable
Belden 2139A Cable 24 AWG 25 Pairs Category 5E Indoor/Outdoor OSP and CM-LS 25pr Multi Conductor UnShielded Solid BC FR PO Jacket Cable

Description:
• CAT5e (100MHz), 25-Pair, Unshielded Pairs, Rated-CM-LS, Indoor/ Outdoor Premise Backbone Cable, 24 AWG solid bare copper conductors, Polyolefin insulation, Polymer Gel Waterblocked, Polyolefin Inner Jacket, Corrugated Aluminum Tape, FR Polyolefin Outer Jacket.

Insulation:
• Material: PO - Polyolefin

Inner Jacket:
• Trade Name: Polyolefin
• Material: Medium Density Polyethylene
• Nom. Wall Thickness (in.): 0.040
• Nom. Diameter (in.): 0.510

Outer Jacket:
• Material: Flame Retardant Polyethylene
• Nom. Wall Thickness (in.): 0.060
• Nom. Diameter (in.): 0.730
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Yes

Outer Jacket over Armor:
• Outer Jacket Material over Armor (y/n): Yes

Outer Jacket Material Over Armor:
• Trade Name: Corrugated Aluminum Tape
• Material: Aluminum
• Nom. Wall Thickness (in.): 0.008
• Nom. Diameter (in.): 0.610

Armor:
• Armor Type: Corrugated Tape
• Armor Material: Aluminum
• Armor Thickness: 0.008
• Diameter over Armor: 0.610

Usage (Overall):
Applications:
• Indoor/Outdoor Premise Backbone Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +75°C
• Installation Temperature Range: -20°C To +60°C
• Operating Temperature Range: -40°C To +60°C
• UL Temperature Rating: 60°C
• Installation Temperature Rating: 60°C
• Bulk Cable Weight: 332 lbs/1000 ft.
• Max. Recommended Pulling Tension: 165 lbs.
• Min. Bend Radius/Minor Axis: 7.500 in.
• Min. Bend/Installation: 14.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM-LS
• CEC/C(UL) Specification: CM-LS
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 5e - TIA 568.C.2
• ANSI Specification: ANSI/ICEA S-99-689, ANSI/ICEA S-107-704 Paragraph 8.2.1 Water Penetration & ANSI/ICEA S-56-434
• Other Specification: NEMA WC-63.1 Category 5e

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 14.000
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 68.000
• Maximum Delay (ns/100 m): 538 @ 100MHz
• Max. Delay Skew (ns/100 m): 45
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5

Flame Test:
• UL Flame Test: UL1581 Vertical Tray

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes - When supported by messenger wire
• Suitability - Aerial: No
• Suitability - Buiral: Yes
• Suitability - Hazardous Locations: No
• Sunlight Resistance: Yes
• Non-halogenated: No

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 24
# pairs 25
stranding solid
no. of conductors 50
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.730
belden cable part number 2139A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question