Belden 8232A Cable 20 AWG Video Triax RG-59/U Type Riser Coax Cable
Select gauge from drop-down menu for prices:
- Belden Cable Video Triax Cable
- Belden 8232 Cable 20 AWG Video Triax RG-59/U Type General Coax PE Jacket Cable
- Belden 1856A Cable 20 AWG Video Triax RG-59/U Type General Coax Cable
- Belden 88232 Cable 20 AWG Video Triax RG-59/U Type Plenum Coax Cable
- Belden 1857A Cable 22 AWG Video Triax RG-59/U Type High Flex General Coax Cable
- Belden 8233A Cable 14 AWG Video Triax RG-11/U Type Riser Coax Cable
- Belden 8233P Cable 14 AWG Video Triax RG-11/U Type Plenum Coax Cable
- Belden 8233WB Cable 14 AWG Video Triax RG-11/U Type Waterblock Coax Cable
- Belden 7803A Cable 14 AWG Video Triax RG-11/U Type Waterblock Coax PE Jacket Cable
- Belden 1858A Cable 15 AWG Video Triax RG-11/U Type High Flex General Coax Cable
- Belden 1859A Cable 15 AWG Video Triax RG-11/U Type High Flex Plenum Coax Cable
Description:
• 20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shields (95% and 80% coverage), PVC jacket.
Insulation:
• Material: Gas-injected FHDPE - Foam High Density Polyethylene
• Dia. (in.): 0.145
Inner Shield:
• Type: Braid
• Material: Bare Copper
Inner Jacket:
• Material: PE - Polyethylene
• Nom. Dia. (in.): 0.225
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
Mechnical Characteristics (Overall):
• Operating Temperature Range: -40°C To +75°C
• UL Temperature Rating: 60°C
• Non-UL Temperature Rating: 75°C
• Bulk Cable Weight: 63 lbs/1000 ft.
• Max. Recommended Pulling Tension:125 lbs.
• Min. Bend Radius/Minor Axis: 3.250 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMG
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: No
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• RG Type: Sub-miniature 59/U
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75
• Nom. Inductance (μH/ft): 0.097
• Nom. Capacitance Conductor to Shield (pF/ft): 16.2
• Nominal Velocity of Propagation VP (%): 83
• Nominal Delay (ns/ft): 1.22
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 10.0
• Nom. Inner Shield DCR @ 20°C (Ohm/1000 ft): 2.5
• Nominal outer Shield DCR @ 20°C (Ohm/1000 ft): 2.8
• Max.Operating Voltage - UL: 300 V RMS
• Sweep Testing: 100% sweep tested 5 MHz to 4.5 GHz.
Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Aerial: Yes - When supported by a messenger wire
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 88232
Benefits and Features:
• Direct burial, riser and plenum options for permanent installations
• Flexible versions available for portable applications
• Multiple jacket options: Belflex for extra flexibility (available in up to 6 different colors) or SCPE thermoset jacket for more rugged applications
technical specification: | |
awg | 20 |
# coax | 1 |
stranding | solid |
number of conductors | 1 |
conductor material | bare copper |
dia. (in.) | 0.032 |
outer shield - type | braid |
outer shield - material | bare copper |
overall cable - nominal dia. (in.) | 0.315 |
belden cable part number | 8232A |