Belden 1213F Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor F/UTP-Foil Shielded Solid BC Flamarrest Jacket Cable

Belden 1213F Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor F/UTP-Foil Shielded Solid BC Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1213F Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor F/UTP-Foil Shielded Solid BC Flamarrest Jacket Cable

Precio habitual $1,584.00 $1,056.00 Oferta /per Foot

Belden 1213F Cable 24 AWG 4 Pairs Category 5E NonBonded-Pair Enhanced Multi Conductor F/UTP-Foil Shielded Solid BC Flamarrest Jacket Cable

Description:
• CAT5e+ (350MHz), 4-Pair, F/UTP-Foil shielded, Plenum-CMP, Premise Horizontal Cable, 24 AWG solid bare copper conductors, FEP insulation, overall Beldfoil® shield, Flamarrest® jacket, RJ-45 compatible.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest (R)
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.235
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, HDBaseT, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments, 100 MHz Category 5e.

Mechanical Characteristics (Overall):
• Operating Temperature Range: 0°C To +75°C
• Bulk Cable Weight: 34 lbs/1000 ft.
• Max. Recommended Pulling Tension: 25 lbs.
• Min. Bend Radius/Minor Axis: 1 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 12/09/2011
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 5e - TIA 568.C.2
• ANSI Specification: ANSI/TIA 568-C.2 Category 5e
• Other Specification: NEMA WC-63.1 Category 5e

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 70
• Maximum Delay (ns/100 m): 538 @ 100MHz
• Max. Delay Skew (ns/100 m): 45
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 1212F

technical specification:
awg 24
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.235
belden cable part number 1213F