Belden 20 AWG 300V PLTC Overall Beldfoil Shielding Orange Communication Cable

Belden 20 AWG 300V PLTC Overall Beldfoil Shielding Orange Communication Cable

Product Details

Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.381

Outer Shield Drian Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
• Outer Jacket Ripcord: Yes

Overall Cabling Lay Length and Direction:
• Direction: Left-hand Lay

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 43.158 Kg/Km
• Max. Recommended Pulling Tension: 71.171 N
• Min. Bend Radius/Minor Axis: 53.340 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Shield (pF/m): 180.455
• Nom. Capacitance Conductor to Conductor (pF/m): 98.43
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 31.1695
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 124.678
• Max. Operating Voltage - UL: 300 V RMS (PLTC CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part number
Action
20 1 5.334 1033A Request A Quote
20 2 8.433 3016A Request A Quote
20 4 9.474 1056A Request A Quote
20 8 11.989 1057A Request A Quote
20 12 14.326 1058A Request A Quote
20 16 16.485 1059A Request A Quote
20 24 19.964 1060A Request A Quote
20 36 24.384 1061A Request A Quote
20 50 28.372 1062A Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question