Belden Cable DeviceNet Cable

Belden Cable DeviceNet Cable

Select gauge from drop-down menu for prices:

Belden Cable DeviceNet Cable
Belden Cable DeviceNet Cable

Belden DeviceNet Cables allow you to configure real-time networks and eliminate costly installation expenses. Designed and manufactured for compliance with ODVA specifications, Belden DeviceNet cables are approved for use within existing cable trays.

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon (15 AWG)
• Material: FEP - Fluorinated Ethylene Propylene (18 AWG)

Inner Shield:
• Material: Aluminum Foil-Polyester Tape (15 AWG Pair and 18 AWG Pair)

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 19x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.060

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• Non-UL Temperature Rating: 75°C
• Bulk Cable Weight: 135 lbs/1000 ft.
• Max. Recommended Pulling Tension: 190 lbs.
• Min. Bend Radius/Minor Axis: 4.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/05
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ODVZ Class 1 Thick

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 120 (18 AWG Pair Only)
• Nom. Capacitance Conductor to Conductor (pF/ft): 12.0 (18 AWG Pair Only)
• Nominal Velocity of Propagation: VP (%): 75 (18 AWG Pair Only)
• Maximum Delay (ns/ft): 1.36 (18 AWG Pair Only)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.6 (15 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.9 (18 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 1.8
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Recommended Current: 8.0 Amps/Conductor @ 25°C (15 AWG)

Flame Test:
• UL Flame Test: UL1685 UL Loading

Suitability:
• Sunlight Resistance: Yes
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

Benefits:
• Open low-cost system link, eliminating the need for hardwiring and traditional cabling practices
• Maximum reliability and performance
• Increased flexibility

Features:
• Reduced cable and installation costs.
• Noise resistant, with both event and timer based options
• Data and power functionality in one cable