Interlocked Armor Power Cable 5kV/8kV UL Type MV-105 Shielded, EPR Insulation 8kV, 100% and 5kV, 133% Insulation Level Aluminum Armor Copper Conductors
Select gauge from drop-down menu for prices:
- Interlocked Armor Power Cable - 2 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 1 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 1/0 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 2/0 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 3/0 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 4/0 Gauge - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 250 MCM - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 350 MCM - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 500 MCM - 3 Conductor - 5kV/8kV
- Interlocked Armor Power Cable - 750 MCM - 3 Conductor - 5kV/8kV
Product Details
Interlocked Armor Power Cable 5kV/8kV UL Type MV-105 Shielded, EPR Insulation 8kV, 100% and 5kV, 133% Insulation Level Aluminum Armor Copper Conductors cable employs three conductors made from soft bare annealed copper available in compressed or compact stranding. The copper conductors meet ASTM requirements B-3 for class B copper wire, B-8 for compressed stranded and B-496 for compact stranded conductors. The conductors are individually insulated with ethylene propylene rubber (EPR) per ICEA S-96-659. A soft bare annealed copper grounding conductor is included in the assembly which helps to ensure steady conductivity throughout the life of the cable. The exterior armor of the cable is an aluminum interlocked tape armor that is also available in galvanized steel. The armor serves as the first line of defense against materials or objects that may pose a threat to the conductors. The armor is coated with a yellow sunlight-resistant PVC jacket.
Interlocked Armor Power Cable 5kV/8kV UL Type MV-105 Shielded, EPR Insulation 8kV, 100% and 5kV, 133% Insulation Level Aluminum Armor Copper Conductors cable is designed to transmit medium voltages at a maximum conductor temperature of 105°C. In emergency overload conditions, conductor can tolerate temperatures up to 140°C and in short circuit conditions, the conductor can tolerate temperatures up to 250°C. The cable is approved for use in wet or dry locations and can be installed indoors or outdoors. The cable can be installed aerially, in ducts, cable trays, conduits, or direct burial for circuits not exceeding 5,000 volts. The cable is approved for use in hazardous locations in accordance with National Electric Code.
Size (AWG or kcmil) |
No. of Conductors |
Ground Wire Size AWG |
Product Code |
Action |
2 Gauge | 3 | 6 | HW315 00203 / HW31500203 |
Request A Quote |
1 Gauge | 3 | 6 | HW315 00103 / HW31500103 |
Request A Quote |
1/0 | 3 | 6 | HW315 10103 / HW31510103 |
Request A Quote |
2/0 | 3 | 4 | HW315 20103 / HW31520103 |
Request A Quote |
3/0 | 3 | 4 | HW315 30103 / HW31530103 |
Request A Quote |
4/0 | 3 | 4 | HW315 40103 / HW31540103 |
Request A Quote |
250 MCM | 3 | 3 | HW315 25003 / HW31525003 |
Request A Quote |
350 MCM | 3 | 3 | HW315 35003 / HW31535003 |
Request A Quote |
500 MCM | 3 | 3 | HW315 50003 / HW31550003 |
Request A Quote |
750 MCM | 3 | 2 | HW315 75003 / HW31575003 |
Request A Quote |