Belden Thermocouple Extension Overall and Individually Beldfoil Shielding Solid Conductor Cable
Select gauge from drop-down menu for prices:
- Belden 3115A 20 AWG 2 Pairs JX ANSI Type Thermocouple Extension Cable Multi Conductor Solid Cable
- Belden 1006A 20 AWG 4 Pairs JX ANSI Type Thermocouple Extension Cable Multi Conductor Solid Cable
- Belden 1012A 20 AWG 4 Pairs KX ANSI Type Thermocouple Extension Cable Multi Conductor Solid Cable
- Belden 1013A 20 AWG 8 Pairs KX ANSI Type Thermocouple Extension Cable Multi Conductor Solid Cable
Product Details
Connect your devices to sensing or controlling equipment with thermocouple wire and extension grade cable from Belden.
With products designed for compliance to American National Standards Institute (ANSI) and IEC standards, Belden has the right solution for your needs.
Benefits:
• Generates measurable electrical energy with dissimilar conductors
• Enhanced performance in high operating temperature environments
• Color coded insulation and jacket materials for easy identification
Features:
• Meets ANSI/IEC Type E/J/K/T/EX/JX/KX/TX standards
• Multiple alloy options for measuring electrical readings
• Additional constructions available upon request
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.4064
Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape
Inner Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
Overall Cabling Lay Length and Direction:
• Length (in.): 5.9
Pair Lay Length and Direction:
• Lay Length (in.): 2.500
• Twists (twist/ft): 4.800
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 48.500 lbs/1000 ft.
• Max. Recommended Pulling Tension: 55.500 lbs.
• Min. Bend Radius/Minor Axis: 3.300 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CEC/C(UL) Specification: CMG
• CSA Specification: FT4
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 1202
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• ANSI Specification: MC 96.1-1982 Type JX
Surface Printing (Overall):
Electrical Characteristics (Overall):
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 6.8
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 10.600 Ohm/1000 ft
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
20 | 2 | 8.433 | 3115A | Request A Quote |
20 | 4 | 9.728 | 1006A | Request A Quote |
20 | 4 | 11.354 | 1012A | Request A Quote |
20 | 8 | 14.529 | 1013A | Request A Quote |