XHHW-2 Tray Cable Unshielded TYPE TC
Select gauge from drop-down menu for prices:
- 14/2 XHHW Tray Cable
- 14/3 XHHW Tray Cable
- 14/4 XHHW Tray Cable
- 14/5 XHHW Tray Cable
- 14/6 XHHW Tray Cable
- 14/7 XHHW Tray Cable
- 14/8 XHHW Tray Cable
- 14/9 XHHW Tray Cable
- 14/10 XHHW Tray Cable
- 14/12 XHHW Tray Cable
- 14/15 XHHW Tray Cable
- 14/19 XHHW Tray Cable
- 14/20 XHHW Tray Cable
- 14/24 XHHW Tray Cable
- 14/25 XHHW Tray Cable
- 14/26 XHHW Tray Cable
- 14/30 XHHW Tray Cable
- 14/36 XHHW Tray Cable
- 14/37 XHHW Tray Cable
- 12/2 XHHW Tray Cable
- 12/3 XHHW Tray Cable
- 12/4 XHHW Tray Cable
- 12/5 XHHW Tray Cable
- 12/6 XHHW Tray Cable
- 12/7 XHHW Tray Cable
- 12/8 XHHW Tray Cable
- 12/9 XHHW Tray Cable
- 12/10 XHHW Tray Cable
- 12/12 XHHW Tray Cable
- 12/15 XHHW Tray Cable
- 12/19 XHHW Tray Cable
- 12/20 XHHW Tray Cable
- 12/24 XHHW Tray Cable
- 12/25 XHHW Tray Cable
- 12/26 XHHW Tray Cable
- 12/30 XHHW Tray Cable
- 12/37 XHHW Tray Cable
- 10/2 XHHW Tray Cable
- 10/3 XHHW Tray Cable
- 10/4 XHHW Tray Cable
- 10/5 XHHW Tray Cable
- 10/7 XHHW Tray Cable
- 10/8 XHHW Tray Cable
- 10/9 XHHW Tray Cable
- 10/10 XHHW Tray Cable
- 10/12 XHHW Tray Cable
- 10/15 XHHW Tray Cable
- 10/19 XHHW Tray Cable
- 10/20 XHHW Tray Cable
- 10/24 XHHW Tray Cable
- 10/25 XHHW Tray Cable
- 10/26 XHHW Tray Cable
- 10/30 XHHW Tray Cable
- 10/36 XHHW Tray Cable
- 10/37 XHHW Tray Cable
Applications:
XHHW-2 Tray Cable Unshielded TYPE TC has a wide range of both commercial and industrial applications because of its heavy duty and tough jacketing. This cable can be directly buried or used above the ground, in free air and in marshy environments. It also used for cabling in; racks, ducts, cable trays and conduits. The cable tray installation is according to Articles 501, 340 and 318 of the NEC.
Conductors:
• Fully stranded soft and bare copper
• Stranded in accordance with the UL standards
Insulation:
• Cross linked polyethylene, XLPE
Color Code:
The individual conductors are color coded in accordance with ICEA Table K-2.
Cabling:
The specified number of conductors are cabled with fillers where needed and a suitable tape is applied over the assembly. Two-conductor cables are flat parallel design.
Overall Jacket:
A heavy-duty polyvinyl chloride (PVC) sheath to meet the requirements of UL Class-12 is applied over the assembled core.
Applications:
Control applications where cable is used in conduit, ducts, trays or racks. It can also be used in free air when supported by a messenger or for direct burial. Can be installed in cable trays per NEC Articles 318, 340 and 501
Features:
• Moisture and sunlight resistant.
• Meets UL 1277 Flame tray test with 70,000 BTU flame source.
• Rated 90°C Dry, 75°C Wet, 600 volt.
• UL Listed as type TC and for aerial use and direct burial.
• Insulated conductors are XHHW-2 type and pass VW-1 flame test.
• Meets appropriate sections of NEC Articles 318, 340 and 501.
Meets NEC:
• Article 318 for Cable Tray Installations.
• Article 340 for Cable Construction.
• Article 501 for Class 1, Div. 2 Hazardous Locations.