Tray Cable - PLTC Shielded Pairs With Overall Shield Type PLTC/ITC-ER - Instrumentation Tray Cable - 300 Volts - 105 Degrees C
Select gauge from drop-down menu for prices:
Tray Cable - PLTC Shielded Pairs With Overall Shield Type PLTC/ITC-ER - Instrumentation Tray Cable - 300 Volts - 105 Degrees C
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 20 AWG - 2 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 20 AWG - 4 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 20 AWG - 8 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 20 AWG - 12 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 20 AWG - 16 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 18 AWG - 2 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 18 AWG - 4 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 18 AWG - 8 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 18 AWG - 12 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 18 AWG - 16 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 16 AWG - 2 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 16 AWG - 4 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 16 AWG - 8 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 16 AWG - 12 Pairs
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE - 300 Volts - 105 Degrees C - 16 AWG - 16 Pairs
Specifications:
- TRAY CABLE - PLTC SHIELDED PAIRS WITH OVERALL SHIELD
- TYPE PLTC/ITC-ER - INSTRUMENTATION TRAY CABLE
- Shielded Pairs with Overall Shield PVC Insulation with Overall PVC Jacket
- 20 - 16 AWG • 300 Volts • 105°C
Description:
ADC’s Type PLTC/ITC-ER shielded pairs with an overall shield have PVC insulation with an overall sunlight resistant PVC jacket.
Application:
Class 1 Division 2 Industrial Hazardous Locations. For use in cable tray, raceway and conduit. For use with audio, intercom, control, energy management, and alarm circuits. For use where sunlight resistance is required.
Construction:
- Conductors: Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Tinned Copper available upon request.
- Insulation PVC Thickness: Per UL 13 Table 7.3
- Cabling: Pairs are cabled with staggered lays and wrapped with a foil free edge aluminum mylar tape. A stranded tinned copper drain wire is pulled in under each tape.
- Overall Shield: Aluminum mylar tape providing 100% coverage with a flexible stranded tinned copper drain wire. Overall Jacket: A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.
- Color Code: Method 1 - Black and White (White conductor in each pair printed alphanumerically for easy identifcation)
Industry Listings & Standards:
Black, Green, White, Red. Print on one side with a contrasting ink. An extruded stripe and other colors are available upon request.- UL Listed as PLTC/ITC per UL Standard 13 and 2250
- Rated -25°C to 105°C
- OSHA Acceptable
- NEC Article 725
- CSA FT4
- IEEE1202 70,000 BTU Flame Test
- ASTM - All Applicable Standards
Size AWG | no. of triads | Appr. weight lbs./m ft. | catalog number | Action |
20 | 2 | 39 | 12002SPOS | Request a Quote |
20 | 4 | 82 | 12004SPOS | Request a Quote |
20 | 8 | 139 | 12008SPOS | Request a Quote |
20 | 12 | 206 | 12012SPOS | Request a Quote |
20 | 16 | 262 | 12016SPOS | Request a Quote |
18 | 2 | 61 | 18002SPOS | Request a Quote |
18 | 4 | 106 | 18004SPOS | Request a Quote |
18 | 8 | 184 | 18008SPOS | Request a Quote |
18 | 12 | 272 | 18012SPOS | Request a Quote |
18 | 16 | 347 | 18016SPOS | Request a Quote |
16 | 2 | 66 | 16002SPOS | Request a Quote |
16 | 4 | 137 | 16004SPOS | Request a Quote |
16 | 8 | 254 | 16008SPOS | Request a Quote |
16 | 12 | 359 | 16012SPOS | Request a Quote |
16 | 16 | 479 | 16016SPOS | Request a Quote |