Belden 18 AWG Pairs 300V PLTC Overall Beldfoil Shield Orange Communication Cable
Select gauge from drop-down menu for prices:
- Belden 1032A 18 AWG 1 Pair 300V PLTC Multi Conductor Cable
- Belden 3025A 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable
- Belden 1529A 18 AWG 3 Pairs 300V PLTC Multi Conductor Cable
- Belden 1466A 18 AWG 4 Pairs 300V PLTC Multi Conductor Cable
- Belden 1467A 18 AWG 8 Pairs 300V PLTC Multi Conductor Cable
- Belden 1468A 18 AWG 12 Pairs 300V PLTC Multi Conductor Cable
- Belden 3034A 18 AWG 16 Pairs 300V PLTC Multi Conductor Cable
- Belden 1471A 18 AWG 24 Pairs 300V PLTC Multi Conductor Cable
- Belden 1472A 18 AWG 36 Pairs 300V PLTC Multi Conductor Cable
- Belden 3041A 18 AWG 50 Pairs 300V PLTC Multi Conductor Cable
Product Details
Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.
No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.406
Outer Shield Drian Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 48.367 Kg/Km
• Max. Recommended Pulling Tension: 115.653 N
• Min. Bend Radius/Minor Axis: 24.130 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 167.331
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/m): 311.695
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 19.2267
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 16.6347
• Max. Operating Voltage - UL: 300 V RMS (PLTC, CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)
• Max. Recommended Current: 8 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Burial: No
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
18 | 1 | 6.020 | 1032A | Request A Quote |
18 | 2 | 9.525 | 3025A | Request A Quote |
18 | 3 | 10.668 | 1529A | Request A Quote |
18 | 4 | 11.557 | 1466A | Request A Quote |
18 | 8 | 14.021 | 1467A | Request A Quote |
18 | 12 | 17.323 | 1468A | Request A Quote |
18 | 16 | 18.110 | 3034A | Request A Quote |
18 | 24 | 24.028 | 1471A | Request A Quote |
18 | 36 | 27.534 | 1472A | Request A Quote |
18 | 50 | 31.496 | 3041A | Request A Quote |