Service Wire Preassembled Aerial Jacketed EPR Non-shielded MV-90 2,400 Volt Copper Cable
Select gauge from drop-down menu for prices:
Service Wire Preassembled Aerial Jacketed EPR Non-shielded MV-90 2,400 Volt Copper Cable
- Service Wire 8 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K8/3E
- Service Wire 6 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K6/3E
- Service Wire 4 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K4/3E
- Service Wire 2 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K2/3E
- Service Wire 1/0 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K1/03E
- Service Wire 2/0 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K8/3E
- Service Wire 4/0 AWG Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/4C2.4K8/3E
- Service Wire 250 MCM Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR3/8C2.4K250/3E
- Service Wire 350 MCM Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR1/2C2.4K350/3E
- Service Wire 500 MCM Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR9/16C2.4K500/3E
- Service Wire 750 MCM Preassembled Aerial Jacketed EPR Non shielded MV-90 2,400 Volt Copper Cable AR9/16C2.4K750/3E
Service Wire Preassembled Aerial Jacketed EPR Non-shielded MV-90 2,400 Volt Copper Cable
Description: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant EPR. Conductors are cabled with a left hand lay and laid parallel to a 30% EHS copperweld messenger then bound with a flat copper binding strap.
Applications: Where NEC jurisdiction applies. 2,400 volt nonshielded power cable (type MV-90) for conductor temperatures not exceeding 90°C.
Standards:
• UL 1072 (single conductors) ICEA S-96-659/NEMA WC-71
• Sunlight Resistant
• RoHS Compliant
size awg/kcmil | strand (no.) | ampacity* (40°c ambient) | service wire part number | Action |
non-shielded | ||||
8 | 7 | 66 | AR1/4C2.4K8/3E | Request a Quote |
6 | 7 | 88 | AR1/4C2.4K6/3E | Request a Quote |
4 | 7 | 115 | AR1/4C2.4K4/3E | Request a Quote |
2 | 7 | 154 | AR1/4C2.4K2/3E | Request a Quote |
1/0 | 19 | 205 | AR1/4C2.4K1/03E | Request a Quote |
2/0 | 19 | 240 | AR5/16C2.4K2/03E | Request a Quote |
4/0 | 19 | 320 | AR3/8C2.4K4/03E | Request a Quote |
250 | 37 | 355 | AR3/8C2.4K250/3E | Request a Quote |
350 | 37 | 440 | AR1/2C2.4K350/3E | Request a Quote |
500 | 37 | 545 | AR9/16C2.4K500/3E | Request a Quote |
750 | 61 | 685 | AR9/16C2.4K750/3E | Request a Quote |