Lapp OLFLEX® VFD 2XL with Signal Flexible 600V UL TC-ER Approval Cable

Lapp OLFLEX® VFD 2XL with Signal 600V UL TC-ER Flexible Cable

ÖLFLEX® VFD 2XL with Signal is a robust oil- and UV-resistant shielded motor cable for VFD drives, with a pair for brake or temperature sensor. The XLPE (plus) insulation with enhanced electrical properties can withstand twice the dielectric voltage test, provides extended performance, and is suitable for 2kV applications.

Construction
Conductors:
• Finely stranded bare copper
Insulation:
• XLPE (plus)
Shielding:
• barrier tape; triple layer foil tape (100% coverage)tinned copper braid (85% coverage)
Jacket:
• specially formulated thermoplastic elastomer (TPE) black
Technical data
Minimum bend radius:
• 7.5 x cable diameter
Temperature range:
• - UL/CSA TC: -25°C to +90°C
• - for stationary use: -40°C to +105°C
• - for flexible use: -25°C to +105°C
Nominal voltage:
• - UL TC: 600V/2000V
• - UL Flexible Motor Supply: 1000V
• - c(UL) CIC/TC: 600V
•- cRU AWM: 1000V
Test voltage:
• 6000V
Conductor stranding:
• - 16 - 6 AWG: Class 5 fine wire
• - 4 - 2 AWG: Class K fine wire
Color code:
• black with white numbers, plus green/yellow ground and one black pair with white numbers
Approvals:
• UL: UL: TC-ER per UL 1277
• Attributes: UL Oil Res I/II
90°C wet or dry
-40°C cold bend; -25°C cold impact
sunlight resistant
direct burial
NFPA 79
bus drop approval
• NEC: Class 1 Division 2 per NEC Article 501
• Canada: c(UL) CIC/TC FT4
cRU AWM I/II A/B FT4
• Additional: CCE (50V - 1kV) & RoHS
Features
• One cable for applications up to 2kV
• Low capacitance design
• Industrial grade phthalate-free jacket designed for harsh environments.
• UL TC-ER & c(UL) CIC/TC approved
• Reduces space and weight in tray
•No conduit required due to TC-ER rating

AWG Number of conductors Nominal Outer
Diameter
Copper Weight
(lbs/mft)
Approx. Weight
(lbs/mft)
Part Number
inches mm
16 AWG (1.5 mm²)
16 4 + (18 AWG) 0.652 16.6 91 200 700710
14 AWG (2.5 mm²)
14 4 + (18 AWG) 0.687 17.4 132 252 700711
12 AWG (4 mm²)
12 4 + (18 AWG) 0.752 19.1 160 294 700712
10 AWG (6 mm²)
10 4 + (18 AWG) 0.798 20.3 215 354 700713
8 AWG (10 mm²)
8 4 + (18 AWG) 0.986 25.0 334 690 700714
6 AWG (16 mm²)
6 4 + (18 AWG) 1.112 28.2 504 905 700715
4 AWG (21 mm²)
4 4 + (18 AWG) 1.259 32.0 667 1125 700716
2 AWG (33.7 mm²)
2 4 + (18 AWG) 1.403 35.6 1027 1580 700717

( ) = shielded pair

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)