Prysmian and Draka Cable ICS IE ToughCat 7S S/FTP Installation Cables for tougher environments
Select gauge from drop-down menu for prices:
Product Details
Conductor: Solid copper wire Ø 0.56 mm (AWG 23)
Insulation: foamskin PE, Ø 1.4 mm
Twisting: 2 cores to the pair
Pair screen: Al-laminated plastic foil
Cable lay up: 4 pairs (PiMF) to the core
Screen: Copper braid, tinned
Sheath: Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1)
Application: Generic Data transmission. This cable is Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units.
Standards:
• EN 50173-1; EN 50288-4-1
• ISO/IEC 11801; IEC 61156-5
• Det Norske Veritas (DNV) specification No. 6-827.50-2
Fire Rating: LSHF-FR(SHF1) - IEC 60754-2; IEC 61034, IEC 60332-3-24
Chemical Resistance:
• Mineral oils IRM 902 (IEC60811-2-1) - 7 days/23°C, 4 hours/70°C
• Diesel - IRM 903 (IEC 60811-2-1) - 7 days/23°C, 4 hours/70°C
Certification: This cable is certified by: Det Norske Veritas (DNV)
description | colour | outer diameter mm |
fire load | weight kg/km |
prysmian and draka cable part number |
|
mj/km | kwh/m | |||||
toughcat7S S/FTP 4x2/0.56 | grey ral7035 |
7.6 | 670 | 0.186 | 64 | 1022322 |
Product Code Table
product description | product code | pg reference code | pg part number |
toughcat c7s lshf-fr 4x2/0.56 | 60015280 | 60015280 | |
toughcat c7 lshf-fr 4x/0.56 500dp | 1022322-00500dp | 60015280 | 60015282 |
Mechanical Properties
bending radius | temperature range | fire load | maximum tensile load | |||
without load | with load | during operation | during installation | 4 pair | during operation | during installation |
8 x d | 4 x d | -40°c to + 85°c | -15°c to + 50°c | 670 mj/km | no load | 200N |