Belden Cable Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable
Select gauge from drop-down menu for prices:
- Belden Cable 16 AWG 4 Conductors Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable 29500F
- Belden Cable 14 AWG 4 Conductors Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable 29501F
- Belden Cable 12 AWG 4 Conductors Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable 29502F
- Belden Cable 10 AWG 4 Conductors Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable 29503F
- Belden Cable 8 AWG 4 Conductors Classic High Flex Premium 300% Ground Foil/Braid Design Continuous Flex VFD Cable 29504F
Product Details
Continuous Flex & Extra Flexible Designs Features:
• Increased range of flexibility, with up to 10M flex cycles for on-machine applications (8AWG and smaller)
• Extreme high-strand conductors ease installation, enable best-in-class vibration resistance with over 2,000 strands on large gauge sizes
• Tinned copper circuit conductors and grounds, TPE jackets for added flexibility
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 300% ground four conductor
• Shielding: Foil + Braid
• Grounding: Full Size Insulated
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Tinned Copper
• Rating: 1000V UL Flexible Motor Supply
• 600V UL 1277 Type TC-ER
• 1000V UL 2277 Type WTTC
• IEEE 1202
• UL Direct Burial
• XHHW-2, RHW-2 rated circuit conductors -14 AWG and larger
• 90°C Wet/Dry
• C(UL) 600V Type CIC TC
• Oil Res I & II
• -40° C cold bend, IEC 60332-3-22 Cat A (flame test)
• Sunlight resistant
• Suitable for Class I, II & III, Division 2 hazardous locations
• UL 1685 Vertical Tray Flame Test
• RoHS compliant
• CE approved
• 10 million flexes – 16 through 8 SWG only
• NFPA79 Compliant for Continuous Flex
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
awg | cond. stranding |
minimum bend radius cont. flex |
belden cable part number |
Action | |
inch | mm | ||||
16 | 65 x 34 | 4.00 | 101.60 | 29500F | Request A Quote |
14 | 104 x 34 | 4.40 | 111.76 | 29501F | Request A Quote |
12 | 7 x 24 x 34 | 5.00 | 127 | 29502F | Request A Quote |
10 | 7 x 37 x 34 | 5.40 | 137.16 | 29503F | Request A Quote |
8 | 4 x 41 x 30 | 7.00 | 177.8 | 29504F | Request A Quote |