Lapp Unitronic® LiHH Shielded Multi-Conductor Communication and Control Cable
Select gauge from drop-down menu for prices:
- Lapp 0037120 24 AWG 2C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037121 24 AWG 3C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037122 24 AWG 4C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037124 24 AWG 6C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037125 24 AWG 7C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037126 24 AWG 8C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037128 24 AWG 12C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037140 22 AWG 2C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037141 22 AWG 3C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037142 22 AWG 4C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037143 22 AWG 5C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037147 22 AWG 12C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037150 20 AWG 2C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037151 20 AWG 3C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037152 20 AWG 4C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037153 20 AWG 5C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037154 20 AWG 7C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037171 18 AWG 3C Unitronic LiHH Shielded Multi-Conductor Control Cable
- Lapp 0037172 18 AWG 4C Unitronic LiHH Shielded Multi-Conductor Control Cable
UNITRONIC® LiHH/LiHCH is a halogen-free multi-conductor cable for communication, signal, and control applications. It is designed for general purpose installations of electrical machinery where human safety is a concern in case of a fire. UNITRONIC® LiHCH has a tinned copper braid for RFI & EMC protection. UNITRONIC® LiHCH (TP) is an overall-shielded multi-paired version for data, communication, and signal applications.
Shielded Construction
Conductors:
• Stranded bare copper
Pairs:
• Special halogen-free compound
Insulation:
• Special halogen-free compound
Shielding:
• Tinned copper braid
Jacket:
• Special halogen-free compound; pebble gray
Technical data
Minimum bend radius:
• - for installation: 6 x cable diameter
Temperature range:
• - for stationary use: -30°C to +80°C
• - for flexible use: - 5°C to +70°C
Nominal voltage:
• 250V
Test voltage:
• 1200V
Conductor stranding:
• Fine wire
Inductance:
• nominal 0.65 mH/km
Mutual capacitance:
• -conductor/conductor: 24 pF/ft
• -conductor/shield: 37 pF/ft
Color code:
• -UNITRONIC® LiHH/LiHCH: DIN 47100
• -UNITRONIC® LiHCH (TP): DIN 47100
Approvals:
• based on VDE 0812
• CE &RoHS
Features
• Low Smoke, Zero Halogen
• European color code DIN 47100
• Extended temperature range of -30°C to +80°C
• Low smoke density and low amount of corrosive gases if on fire
AWG | Number of Conductors |
Nominal Outer Diameter |
Copper weight (lbs/mft) |
Approx.weight (lbs/mft) |
Part Number |
|
inches | mm | |||||
24 AWG (0.25 mm²) | ||||||
24 | 2 | 0.157 | 4.0 | 4 | 15 | 0037120 |
24 | 3 | 0.165 | 4.2 | 5 | 17 | 0037121 |
24 | 4 | 0.177 | 4.5 | 7 | 19 | 0037122 |
24 | 6 | 0.209 | 5.3 | 10 | 26 | 0037124 |
24 | 7 | 0.209 | 5.3 | 12 | 28 | 0037125 |
24 | 8 | 0.252 | 6.4 | 13 | 34 | 0037126 |
24 | 12 | 0.283 | 7.2 | 20 | 45 | 0037128 |
22 AWG (0.34 mm²) | ||||||
22 | 2 | 0.173 | 4.4 | 5 | 19 | 0037140 |
22 | 3 | 0.181 | 4.6 | 7 | 20 | 0037141 |
22 | 4 | 0.197 | 5.0 | 9 | 27 | 0037142 |
22 | 5 | 0.224 | 5.7 | 11 | 30 | 0037143 |
22 | 12 | 0.315 | 8.0 | 27 | 65 | 0037147 |
20 AWG (0.5 mm²) | ||||||
20 | 2 | 0.193 | 4.9 | 7 | 21 | 0037150 |
20 | 3 | 0.205 | 5.2 | 10 | 25 | 0037151 |
20 | 4 | 0.228 | 5.8 | 13 | 30 | 0037152 |
20 | 5 | 0.248 | 6.3 | 17 | 39 | 0037153 |
20 | 7 | 0.276 | 7.0 | 23 | 48 | 0037154 |
18 AWG (1 mm²) | ||||||
18 | 3 | 0.240 | 6.1 | 20 | 38 | 0037171 |
18 | 4 | 0.260 | 6.6 | 26 | 45 | 0037172 |