Prysmian Cable 35kV TRXLPE URD 100% Copper Medium Voltage Utility Cables
Select gauge from drop-down menu for prices:
- Prysmian Cable 1/0 Solid 35kV 100% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables QB7010A
- Prysmian Cable 1/0 AWG 35kV 100% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables QB8010A
- Prysmian Cable 2/0 AWG 35kV 100% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables QB9010A
- Prysmian Cable 3/0 AWG 35kV 100% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables QBA010A
- Prysmian Cable 4/0 AWG 35kV 100% Copper Single Phase Full Neutral TRXLPE URD Medium Voltage Utility Cables QBB010A
- Prysmian Cable 1/0 Solid 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QB7000A
- Prysmian Cable 1/0 AWG 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QB8000A
- Prysmian Cable 2/0 AWG 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QB9000A
- Prysmian Cable 3/0 AWG 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBA000A
- Prysmian Cable 4/0 AWG 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBB000A
- Prysmian Cable 250 MCM 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBC000A
- Prysmian Cable 350 MCM 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBD000A
- Prysmian Cable 500 MCM 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBE000A
- Prysmian Cable 750 MCM 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBF000A
- Prysmian Cable 1000 MCM 35kV 100% Copper Three Phase One Third Neutral TRXLPE URD Medium Voltage Utility Cables QBG000A
Product Details
Conductors: Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.
Insulation: Natural high dielectric strength VOLTENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires, helically applied and uniformly spaced.
Jacket: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.
Description: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket.
Options:
• Black LLDPE jacket with no stripes
• Black PVC jacket sleeved over separator tape
• No Jacket
• Multiplex cables
• Tinned round and flat strap neutrals
• Compact stranded conductors
• Strandseal®
• Super smooth conductor shield
• UL MV-90 Rating if required
• 46kV
• RUS Bulletin 1728F-U1 where applicable
Installation:
• Conduit in Air
• Direct Buried
• Underground Duct
• Isolated in Air
• Wet Locations
• Dry Locations
• With Messenger
• Utility Primary
Specifications and ratings:
• AEIC- AEIC CS8
• ICEA- ICEA S-94-649
• For 90°C continuous, 130°C emergency, 250°C short-circuit operation.
conductor | insulation thickness (mils) |
concentric neutral |
cond. dia.(in) |
ins. dia. (in) |
ins. shield diameter (in) |
jacket dia.(in) |
cable weight (lbs/kft) |
min. bending radius (in) |
† amp. (amps) |
+/- sequence imp. resistance (µΩ/ft) |
+/- sequence imp. reactance (µΩ/ft) |
† amp. (amps) |
+/- sequence imp. resistance (µΩ/ft) |
+/- sequence imp. reactance (µΩ/ft) |
prysmian cable part number |
(a) | (b) | (c) | (d) | 90°c in duct | 90°c direct buried | ||||||||||
35kv 100% copper single phase - full neutral | |||||||||||||||
1/0 solid cu | 345 | 16-#12 | 0.325 | 1.07 | 1.15 | 1.42 | 1239 | 12 | 215 | 256 | 36 | 276 | 256 | 36 | QB7010A |
1/0 awg cu | 345 | 16-#12 | 0.364 | 1.10 | 1.19 | 1.46 | 1274 | 12 | 217 | 258 | 34 | 278 | 258 | 34 | QB8010A |
2/0 awg cu | 345 | 13-#10 | 0.408 | 1.15 | 1.24 | 1.55 | 1516 | 13 | 248 | 203 | 33 | 316 | 203 | 33 | QB9010A |
3/0 awg cu | 345 | 16-#10 | 0.458 | 1.20 | 1.29 | 1.60 | 1749 | 13 | 281 | 163 | 31 | 358 | 163 | 31 | QBA010A |
4/0 awg cu | 345 | 16-#9 | 0.515 | 1.26 | 1.34 | 1.74 | 2141 | 14 | 319 | 130 | 30 | 402 | 130 | 30 | QBB010A |
35kv 100% copper three phase - one-third neutral | |||||||||||||||
1/0 solid cu | 345 | 9-#14 | 0.325 | 1.07 | 1.15 | 1.39 | 1016 | 12 | 216 | 126 | 54 | 277 | 137 | 97 | QB7000A |
1/0 awg cu | 345 | 9-#14 | 0.364 | 1.10 | 1.19 | 1.43 | 1050 | 12 | 216 | 129 | 53 | 278 | 139 | 95 | QB8000A |
2/0 awg cu | 345 | 11-#14 | 0.408 | 1.15 | 1.24 | 1.47 | 1188 | 12 | 245 | 103 | 51 | 311 | 115 | 92 | QB9000A |
3/0 awg cu | 345 | 14-#14 | 0.458 | 1.20 | 1.29 | 1.52 | 1365 | 13 | 278 | 82 | 49 | 347 | 96 | 87 | QBA000A |
4/0 awg cu | 345 | 18-#14 | 0.515 | 1.26 | 1.34 | 1.58 | 1586 | 13 | 314 | 66 | 47 | 383 | 83 | 83 | QBB000A |
250 MCM cu | 345 | 21-#14 | 0.561 | 1.31 | 1.40 | 1.70 | 1848 | 14 | 344 | 57 | 47 | 409 | 74 | 79 | QBC000A |
350 MCM cu | 345 | 18-#12 | 0.664 | 1.41 | 1.50 | 1.83 | 2363 | 15 | 408 | 42 | 44 | 461 | 62 | 70 | QBD000A |
500 MCM cu | 345 | 17-#10 | 0.794 | 1.54 | 1.66 | 2.03 | 3194 | 17 | 480 | 32 | 42 | 510 | 53 | 59 | QBE000A |
750 MCM cu | 345 | 20-#9 | 0.974 | 1.73 | 1.85 | 2.25 | 4410 | 18 | 561 | 25 | 38 | 573 | 44 | 47 | QBF000A |
1000 MCM cu | 345 | 21-#8 | 1.124 | 1.88 | 2.00 | 2.43 | 5601 | 20 | 609 | 22 | 36 | 626 | 38 | 39 | QBG000A |