HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors
Select gauge from drop-down menu for prices:
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 2 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 8 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 16 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 24 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 50 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 2 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 3 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 6 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 8 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 12 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 16 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 24 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 36 Pairs
- HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 50 Pairs
The HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable employs 7-strand, Class B, soft bare annealed copper conductors. The annealed copper products used in this cable offers increased flexibility compared to standard copper. The cable meets ASTM specifications B3 for annealed cable, and B8 for concentric-lay-stranded cables. The HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable is insulated with flame-retardant polyvinyl chloride (PVC) insulation. The insulated conductors are shielded with an aluminum-polymer tape, providing 100% coverage with a flexible 7-strand tinned copper drain wire. A PVC jacket serves as the outer layer of the cable. The cable’s construction offers excellent resistance to flame, sunlight, and chemicals.
The HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable is used in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. The cable may be used in NEC Class 1, Division 2 hazardous locations.
cond. Size (AWG) | No. of Pairs | Net weight Lbs/Mft | Catalog Number | Action |
18 | 2 | 82 |
HW106 01802 / HW10601802 |
Request a Quote |
18 | 4 | 146 |
HW106 01804 / HW10601804 |
Request a Quote |
18 | 8 | 279 |
HW106 01808 / HW10601808 |
Request a Quote |
18 | 12 | 391 |
HW106 01812 / HW10601812 |
Request a Quote |
18 | 16 | 494 |
HW106 01824 / HW10601824 |
Request a Quote |
18 | 24 | 752 |
HW106 01824 / HW10601824 |
Request a Quote |
18 | 36 | 1053 |
HW106 01836 / HW10601836 |
Request a Quote |
18 | 50 | 1300 |
HW106 01850 / HW10601850 |
Request a Quote |
16 | 2 | 105 |
HW106 01602 / HW10601602 |
Request a Quote |
16 | 3 | 136 |
HW106 01603 / HW10601603 |
Request a Quote |
16 | 4 | 207 |
HW106 01604 / HW10601604 |
Request a Quote |
16 | 6 | 257 |
HW106 01606 / HW10601606 |
Request a Quote |
16 | 8 | 349 |
HW106 01608 / HW10601608 |
Request a Quote |
16 | 12 | 528 |
HW106 01612 / HW10601612 |
Request a Quote |
16 | 16 | 623 |
HW106 01616 / HW10601616 |
Request a Quote |
16 | 24 | 944 |
HW106 01624 / HW10601624 |
Request a Quote |
16 | 36 | 1331 |
HW106 01636 / HW10601636 |
Request a Quote |
16 | 50 | 1731 |
HW106 01650 / HW10601650 |
Request a Quote |