Prysmian and Draka Cable ExpressLT Dry Loose Tube Cable 2.5mm

Prysmian and Draka Cable ExpressLT Dry Loose Tube Cable 2.5mm

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable ExpressLT Dry Loose Tube Cable 2.5mm

Product Details

Prysmian’s popular ExpressLT™ cable combines buffer tubes with enhanced flexibility, a completely dry water-blocking system, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage.

Applications: Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored)

Constructions: Dielectric, armored, double armored, dual jacket

Count: 4 to 432 fibers in color-coded buffer tubes

Fiber Types: Single-mode, multimode, bend-insensitive SM, NZDS

Options: Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped Jacket, factory-installed pulling eye

Similar Alternatives: Gel-filled buffer tubes / LT 2.0 / heavy duty / central / indoor-outdoor / indoor / self-support / microduct

Performance: Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11

Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

Features and Benefits:
Easy Cable Entry and Preparation
• Dry water-blocked core speeds cable access
• Dry water-blocked tubes reduce prep time by an average of 15 minutes per cable end
• Available with ezPREP® armor to allow easy access to the core in mid-sheath entries
• Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core
• Ripcord speeds cable entry & outer jacket removal

Available with ezPREP® Armor
• The jacket can be easily separated from the armor without a heat gun or torch
• Armored cable access, bonding and grounding are faster, easier and safer

Flexible Routing and Termination
• Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20'
• 2.5 mm buffer tubes with enhanced flexibility simplify routing and splice preparation

Multi-Purpose Design
• Suitable for aerial lashed, duct, and direct buried installation (when armored)
• Small diameter and light weight, extends reel and installation lengths
• Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance

fiber count # of buffer
tubes
diameter
inches
(mm)
approximate
cable weight
lb/kft (kg/km)
bend radius
load inches
(cm)
bend radius
no load
inches
(cm)
dielectric (non-armored) (edh1jkt)
4 to 60 5 0.40 (10.1) 43 (64) 8 (20) 4 (10)
62 to 72 6 0.43 (10.9) 50 (75) 8 (22) 4 (11)
74 to 96 8 0.50 (12.6) 65 (97) 10 (25) 5 (13)
98 to 120 10 0.55 (14.1) 81 (121) 11 (28) 6 (14)
122 to 144 12 0.63 (15.9) 105 (156) 13 (32) 6 (16)
146 to 216 18 0.63 (15.9) 105 (156) 13 (32) 6 (16)
228 to 264 22 0.68 (17.3) 128 (190) 14 (35) 7 (17)
276 to 288 24 0.72 (18.3) 145 (216) 14 (37) 7 (18)
290 to 432 36 0.80 (20.4) 154 (229) 16 (41) 8 (21)
single jacket armored (sp) (edh1a1j)
4 to 60 5 0.46 (11.8) 89 (132) 9 (24) 5 (12)
62 to 72 6 0.50 (12.6) 97 (145) 10 (25) 5 (13)
74 to 96 8 0.56 (14.3) 125 (186) 11 (29) 6 (14)
98 to 120 10 0.62 (15.8) 148 (220) 12 (32) 6 (16)
122 to 144 12 0.69 (17.6) 176 (262) 14 (35) 7 (18)
146 to 216 18 0.70 (17.9) 176 (262) 14 (36) 7 (18)
228 to 264 22 0.76 (19.4) 196 (291) 15 (39) 8 (19)
276 to 288 24 0.81 (20.7) 214 (319) 16 (42) 8 (21)
290 to 432 36 0.90 (23.0) 230 (342) 18 (46) 9 (23)
double jacket single armored (psp) (edh1a2j)
4 to 60 5 0.53 (13.5) 107 (160) 11 (27) 5 (14)
62 to 72 6 0.55 (14.0) 122 (181) 11 (28) 5 (14)
74 to 96 8 0.61 (15.5) 137 (204) 12 (31) 6 (16)
98 to 120 10 0.67 (17.1) 167 (249) 13 (34) 7 (17)
122 to 144 12 0.74 (18.9) 198 (294) 15 (38) 7 (19)
146 to 216 18 0.76 (19.2) 198 (294) 15 (38) 8 (19)
228 to 264 22 0.80 (20.4) 220 (327) 16 (41) 8 (20)
276 to 288 24 0.86 (21.8) 239 (356) 17 (44) 9 (22)
290 to 432 36 0.94 (24.0) 257 (382) 19 (48) 9 (24)
dielectric double jacket (pdp) (edhna2j)
4 to 60 5 0.46 (11.7) 63 (96) 9 (23) 5 (12)
62 to 72 6 0.48 (12.2) 73 (108) 10 (25) 5 (12)
74 to 96 8 0.54 (13.8) 89 (133) 11 (28) 5 (14)
98 to 120 10 0.61 (15.4) 111 (165) 12 (31) 6 (15)
122 to 144 12 0.67 (17.1) 133 (198) 13 (34) 7 (17)
146 to 216 18 0.67 (17.1) 137 (204) 13 (34) 7 (17)
218 to 264 22 0.74 (18.7) 159 (237) 15 (37) 7 (19)
266 to 288 24 0.78 (19.8) 179 (266) 16 (40) 8 (20)
double jacket double armored (spsp) (edh2a2j)
4 to 60 5 0.64 (16.3) 182 (272) 13 (33) 6 (16)
62 to 72 6 0.67 (17.1) 194 (289) 13 (34) 7 (17)
74 to 96 8 0.75 (19.1) 226 (336) 15 (38) 8 (19)
98 to 120 10 0.80 (20.4) 258 (384) 16 (41) 8 (20)
122 to 144 12 0.88 (22.4) 312 (465) 18 (45) 9 (22)
146 to 216 18 0.88 (22.4) 305 (454) 18 (45) 9 (22)
218 to 264 22 0.94 (23.9) 338 (503) 19 (48) 9 (24)
266 to 288 24 0.98 (24.9) 368 (547) 20 (50) 10 (25)
triple jacket double armored (pspsp) (edh2a3j)
4 to 60 5 0.70 (17.8) 215 (320) 14 (36) 7 (18)
62 to 72 6 0.73 (18.6) 228 (339) 15 (37) 7 (19)
74 to 96 8 0.78 (19.9) 265 (394) 16 (40) 8 (20)
98 to 120 10 0.86 (21.9) 313 (466) 17 (43) 9 (22)
122 to 144 12 0.93 (23.7) 367 (546) 19 (47) 9 (24)
146 to 216 18 0.93 (23.7) 367 (546) 19 (47) 9 (24)
218 to 264 22 0.98 (25.0) 402 (598) 20 (50) 10 (25)
266 to 288 24 1.02 (26.0) 429 (639) 20 (52) 10 (26)

QUESTIONS & ANSWERS