Belden Cable Category 5E Cable

Belden Cable Category 5E Cable

Select gauge from drop-down menu for prices:

Belden Cable Category 5E Cable

Product Details

Belden offers several Category 5E performance levels. Our top-of-line 1200 series system cable provides headroom beyond the TIA 568-C.2 Category 5E standard and is offered with the Bonded-Pair technology option which will give you peace of mind by making your installation as robust as possible. We also offer minimum compliant versions.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene

Outer Jacket:
• Trade Name: Flamarrest (R)
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.195
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 22 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 0.500 in.
• Min. Bend/Installation: 2 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 5e - TIA 568.C.2
• Other Specification: NEMA WC-63.1 Category 5e, UL Verified to Category 5e

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 66
• Nominal Velocity of Propagation: VP (%): 72
• Maximum Delay (ns/100 m): 510
• Max. Delay Skew (ns/100 m): 25
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9
• Max. Operating Voltage - UL: 80 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3

Flame Test:
• UL Flame Test: NFPA 262
• C/(UL) Flame Test: FT6
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Aerial: No
• Suitability - Buiral: No
• Sunlight Resistance: No - Indoor

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 1700A

Benefits:
• Improved signal strength
• Improved crosstalk and signal-to-noise performance
• Improved system uptime

Features:
• Larger copper
• Less pair-to-pair coupling
• Bonded-Pair technology option

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question