Belden 16 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable

Belden 16 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable

Product Details

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.1938
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 46 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 1.200 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.20
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 4.200
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 5.070
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 8 Amps/conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 Vertical Tray Flame Test
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part number
Action
16 1 7.620 1118A Request A Quote
16 1 7.620 3090A Request A Quote
16 2 11.582 1069A Request A Quote
16 3 12.334 1527A Request A Quote
16 4 14.224 1070A Request A Quote
16 8 17.170 1071A Request A Quote
16 12 20.625 1072A Request A Quote
16 16 24.028 1073A Request A Quote
16 24 29.413 1074A Request A Quote
16 36 33.553 1089A Request A Quote
16 50 39.395 1090A Request A Quote