Lapp OLFLEX® CHAIN 90 CP Single Conductor Shielded Flexible Control Cable
Select gauge from drop-down menu for prices:
- Lapp 1026547 16 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026548 14 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026549 12 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026550 10 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026551 8 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026553 6 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026555 4 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026557 2 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026559 1 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026561 2/0 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026563 3/0 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026565 4/0 AWG 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026567 250MCM 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026569 350MCM 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026571 450MCM 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
- Lapp 1026573 500MCM 1C OLFLEX CHAIN 90 CP Shielded Flexible Cable
ÖLFLEX® CHAIN 90 CP with tinned copper braid shielding is used for applications where EMI emissions need to be suppressed.
Construction
Conductors
• Finely stranded bare copper
Insulation
• Special black or green/yellow compound based on TPE
Shielding
• Tinned copper braid
Jacket
• Polyurethane; black
Technical Data
Minimum Bend Radius:
• for installation: 3 x cable diameter
• for continuous flexing: 7.5 x cable diameter
Temperature Range:
• for continuous flexing: -35°C to +80°C
• for flexible use: -50°C to +80°C
Nominal Voltage:
• UL/CSA: 1000V
• IEC U0/U: 600/1000V
Test Voltage:
• 4000V
Conductor Stranding:
• Class 6 super fine wire
Standards:
• CE, RoHS
Features:
• Suitable for heavy duty power chain applications
• Can substitute multi-conductor power cables where space requirements can cause problems
• Suitable for dry or damp interior use
• Available in larger conductor sizes for power applications
• CSA FT1 flame retardant
AWG | No. of Conductors (incl. ground) |
Nominal Outer Diameter |
Copper Weight (lbs/mft) |
Approx. Weight (lbs/mft) |
Part Number | |
inches | mm | |||||
16 AWG (1.5 mm2) | ||||||
16 | 1 | 0.276 | 7 | 16 | 40 | 1026547 |
14 AWG (2.5 mm2) | ||||||
14 | 1 | 0.299 | 7.6 | 28 | 61 | 1026548 |
12 AWG (4 mm2) | ||||||
12 | 1 | 0.311 | 7.9 | 40 | 67 | 1026549 |
10 AWG (6 mm2) | ||||||
10 | 1 | 0.331 | 8.4 | 55 | 81 | 1026550 |
8 AWG (10 mm2) | ||||||
8 | 1 | 0.386 | 9.8 | 83 | 121 | 1026551 |
6 AWG (16 mm2) | ||||||
6 | 1 | 0.445 | 11.3 | 126 | 161 | 1026553 |
4 AWG (25 mm2) | ||||||
4 | 1 | 0.512 | 13 | 189 | 229 | 1026555 |
2 AWG (35 mm2) | ||||||
2 | 1 | 0.559 | 14.2 | 268 | 323 | 1026557 |
1 AWG (50 mm2) | ||||||
1 | 1 | 0.661 | 16.8 | 371 | 410 | 1026559 |
2/0 AWG (70 mm2) | ||||||
2/0 | 1 | 0.752 | 19.1 | 520 | 592 | 1026561 |
3/0 AWG (95 mm2) | ||||||
3/0 | 1 | 0.850 | 21.6 | 698 | 781 | 1026563 |
4/0 AWG (120 mm2) | ||||||
4/0 | 1 | 0.929 | 23.6 | 860 | 929 | 1026565 |
250MCM (150 mm2) | ||||||
250MCM | 1 | 1.020 | 25.9 | 1089 | 1124 | 1026567 |
350MCM (185 mm2) | ||||||
350MCM | 1 | 1.122 | 28.5 | 1317 | 1332 | 1026569 |
450MCM (240 mm2) | ||||||
450MCM | 1 | 1.315 | 33.4 | 1690 | 1750 | 1026571 |
500MCM (300 mm2) | ||||||
500MCM | 1 | 1.390 | 35.3 | 2097 | 2160 | 1026573 |