Conductors: Solid or Class B Compressed concentric strand Aluminum alloy 1350 or soft drawn annealed copper per ASTM. 

Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. 

Insulation: Natural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life. 

Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. 

Metallic Shield: Solid bare copper wires, helically applied and uniformly spaced. 

Jacket: Black, insulating, sunlight resistant, linear low density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. 

Description: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket. 

Options: 
• Black LLDPE jacket with no stripes 
• Black PVC jacket sleeved over separator tape 
• No Jacket 
• Multiplex cables 
• Tinned round and flat strap neutrals 
• Strandseal® 
• Compact stranded conductors 
• UL MV-90 Rating if required 
• 46kV 
• RUS - Bulletin 1728F-U1 

Installation: 
• Conduit in Air 
• Underground Duct 
• Wet Locations 
• With Messenger 
• Direct Buried 
• Isolated in Air 
• Dry Locations 
• Utility Primary 

Specifications and ratings:
• AEIC- AEIC CS8 
• ICEA- ICEA S-94-649 
• For 105°C continuous, 140°C emergency, 250°C short-circuit operation.

conductor insulation
thickness
(mils)
concentric
neutral
cond.
dia.(in)
ins.
dia.
(in)
ins.
shield
diameter (in)
jacket
dia.(in)
cable
weight
(lbs/kft)
min.
bending
radius (in)

amp.
(amps)
+/- sequence
imp.
resistance
(µΩ/ft)
+/- sequence
imp.
reactance
(µΩ/ft)

amp.
(amps)
+/- sequence
imp.
resistance
(µΩ/ft)
+/- sequence
imp.
reactance
(µΩ/ft)
prysmian Cable
part
number
(a) (b) (c) (d) 105°c in duct 105°c direct buried
15kv 100% copper single phase - full neutral
1/0 solid cu 345 16-#12 0.325 1.07 1.16 1.43 1327 12 234 268 36 298 268 36 QQ7010A
1/0 awg cu 345 16-#12 0.364 1.11 1.20 1.47 1366 12 236 270 34 300 270 34 QQ8010A
2/0 awg cu 345 13-#10 0.408 1.15 1.24 1.56 1614 13 270 212 33 270 212 33 QQ9010A
3/0 awg cu 345 16-#10 0.458 1.20 1.29 1.61 1853 13 306 170 31 386 170 31 QQA010A
4/0 awg cu 345 16-#9 0.515 1.26 1.35 1.75 2252 14 348 136 30 434 136 30 QQB010A
15kv 100% copper three phase - one third neutral
1/0 solid cu 345 9-#14 0.325 1.07 1.16 1.40 1104 12 235 132 54 299 142 97 QQ7000A
1/0 awg cu 345 9-#14 0.364 1.11 1.20 1.44 1142 12 235 134 53 300 144 95 QQ8000A
2/0 awg cu 345 11-#14 0.408 1.15 1.24 1.48 1286 12 267 107 51 337 119 92 QQ9000A
3/0 awg cu 345 14-#14 0.458 1.20 1.29 1.53 1469 13 302 86 49 376 99 88 QQA000A
4/0 awg cu 345 18-#14 0.515 1.26 1.35 1.59 1697 13 342 69 47 415 85 83 QQB000A
250 mcm cu 345 21-#14 0.561 1.31 1.40 1.70 1965 14 375 59 47 443 76 79 QQC000A
350 mcm cu 345 18-#12 0.664 1.42 1.51 1.84 2493 15 445 44 44 501 64 71 QQD000A
500 mcm cu 345 17-#10 0.794 1.55 1.67 2.04 3340 17 525 33 42 557 54 60 QQE000A
750 mcm cu 345 20-#9 0.974 1.73 1.85 2.25 4578 19 616 26 39 624 45 48 QQF000A
1000 mcm cu 345 21-#8 1.124 1.88 2.00 2.43 5787 20 671 23 36 682 39 40 QQG000A