Helukabel MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable
Select gauge from drop-down menu for prices:
- Helukabel 10 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25888
- Helukabel 10 AWG 1 Core 6 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25269
- Helukabel 8 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25889
- Helukabel 8 AWG 1 Core 10 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25270
- Helukabel 6 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25890
- Helukabel 6 AWG 1 Core 16 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25271
- Helukabel 4 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25891
- Helukabel 4 AWG 1 Core 25 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25272
- Helukabel 2 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25892
- Helukabel 2 AWG 1 Core 35 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25273
- Helukabel 1 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25893
- Helukabel 1 AWG 1 Core 50 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25274
- Helukabel 2/0 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25894
- Helukabel 2/0 AWG 1 Core 70 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25275
- Helukabel 3/0 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25895
- Helukabel 3/0 AWG 1 Core 95 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25276
- Helukabel 250 MCM 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25897
- Helukabel 250 MCM 1 Core 150 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25278
- Helukabel 350 MCM 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25898
- Helukabel 350 MCM 1 Core 185 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25279
- Helukabel 4/0 AWG 1 Core 120 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25277
- Helukabel 4/0 AWG 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25896
- Helukabel 450 MCM 1 Core 240 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25280
- Helukabel 450 MCM 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25899
- Helukabel 550 MCM 1 Core 300 mm² Corss-Sec. MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Meter Marking Cable 25281
- Helukabel 550 MCM 1 Core MultiSpeed 600-PUR -J/-O Special Single Cores For Drag Chains 1000V Halogen Free Meter Marking Cable 25900
Product Details
Technical Data:
• Special drag chain core line for extreme mechanical stresses adapted to DIN VDE 0285-525-2-31/DIN EN 50525-2-31 and UL style 10553
Temperature Range:
• flexing -30°C to +80°C
• fixed installation -40°C to +80°C
Nominal Voltage:
• VDE U0/U 600/1000 V
• UL/CSA 1000 V
Test Voltage: 3000 V
Insulation Resistance:
• min. 100 MOhm x km
Minimum Bending Radius:
• flexing 5x core Ø
• fixed installation 3x core Ø
Cable Structure:
• Bare copper conductor, ultra-fine wire to DIN VDE 0295 cl.6, column 4, BS 6360 cl.6 and/or IEC 60228 cl.6
• Core insulation of thermoplastic polymer in either black or green/yellow
• Outer sheath of special polyurethane, TMPU adapted to DIN VDE 0207-363-10-2 / DIN EN 50363-10-2
• Sheath colour black (RAL 9005)
• With meter marking
Properties:
• Flame retardant, UL VW-1, CSA FT1
• Halogen-free
• Abrasion resistant
• Very good oil resistance
• Very good alternating bending strength
• Very high resistance to mechanical stresses
• Higher notch resistance
• Ozone and UV-resistant
• Coolant resistant
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: MULTISPEED® 600-C-PUR-J/O
Application:
• These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements. Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance. For applications extending beyond standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please read the instructions.
• = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.