Belden 16 AWG Triads 300V PLTC Overall Beldfoil Shielding Orange Communication Cable

Belden 16 AWG Triads 300V PLTC Overall Beldfoil Shielding Orange Communication Cable

Product Details

Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.406

Outer Shield Drian Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.940
• Outer Jacket Ripcord: Yes

Pair Lay Length and Direction:
• Twists (twist/m): 6

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 86.762 Kg/Km
• Max. Recommended Pulling Tension: 271.340 N
• Min. Bend Radius/Minor Axis: 28.956 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.511836
• Nom. Capacitance Conductor to Conductor (pF/m): 177.502
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/m): 319.241
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 12.1397
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 16.0769
• Max. Operating Voltage - UL: 300 V RMS

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads overall cable-
nominal
dia. (mm)
belden cable
part number
Action
16 1 7.239 1031A Request A Quote
16 2 12.268 3044A Request A Quote
16 4 14.376 3046A Request A Quote
16 8 19.202 3048A Request A Quote
16 16 26.187 3052A Request A Quote
16 24 33.147 3054A Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question