Lapp OLFLEX® VFD SLIM Reduced diameter Shielded Cable UL and c(UL)
Select gauge from drop-down menu for prices:
- Lapp 761804 18 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 761604 16 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 761404 14 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 761204 12 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 761004 10 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 760804 8 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 760604 6 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 760404 4 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
- Lapp 760204 2 AWG 4C OLFLEX VFD SLIM Reduced diameter Shielded Cable
ÖLFLEX® VFD SLIM is a reduced-diameter shielded motor cable for VFD drives. It is designed with the LAPP Surge Guard insulation system, which includes a semiconductive layer made to withstand nonlinear power distortions associated with VFD drives and to disperse increases in voltage caused by wave reflection, spikes, in-rush current, and harmonics. It is resistant to a wide range of disinfecting solutions used in the food, beverage, chemical and related industries.
Construction
Conductors
• Finely stranded tinned copper
Insulation
• LAPP Surge Guard insulation system
Shielding
• Barrier tape; triple layer foil tape (100% coverage); tinned copper braid (85% coverage)
Jacket
• Specially formulated thermoplastic polymer; black
Technical Data
Minimum Bend Radius:
• 7.5 x cable diameter
Temperature Range:
• UL/CSA TC: -25°C to +90°C
• for stationary use: -40°C to +105°C
• for flexible use: -25°C to +105°C
Nominal Voltage:
• UL/CSA TC: 600V
• UL WTTC: 1000V
• UL Flexible Motor Supply: 1000V
• UL/CSA AWM: 1000V
Test Voltage:
• 2000V
Peak Voltage:
• 7500V
Conductor Stranding:
• 18 - 6 AWG: Class 5 fine wire*
• 4 - 2 AWG: Class K fine wire*
• * 18 AWG meets only Class 5 cross section and DC resistance
Color code:
• Black with white numbers, plus green/yellow ground
Standards:
• UL, ULTC, CSA, CE, RoHS
Features:
• LAPP Surge Guard insulation protection
• UL TC-ER & c(UL) CIC/TC approved
• Double shielded for extra protection
• Resistant to a wide range of disinfecting solutions used in the food, beverage, chemical and related industries, according to ECOLAB® PM 40-1 test procedure
AWG | No. of Conductors (incl. ground) |
Nominal Outer Diameter |
Copper Weight (lbs/mft) |
Approx. Weight (lbs/mft) |
Part Number | |
inches | mm | |||||
18 AWG (1 mm2) | ||||||
18 | 4 | 0.394 | 10.0 | 53 | 112 | 761804 |
16 AWG (1.5 mm2) | ||||||
16 | 4 + drain | 0.465 | 11.8 | 73 | 154 | 761604 |
14 AWG (2.5 mm2) | ||||||
14 | 4 | 0.514 | 13.1 | 100 | 194 | 761404 |
12 AWG (4 mm2) | ||||||
12 | 4 | 0.583 | 14.8 | 139 | 254 | 761204 |
10 AWG (6 mm2) | ||||||
10 | 4 | 0.697 | 17.7 | 195 | 346 | 761004 |
8 AWG (10 mm2) | ||||||
8 | 4 | 0.829 | 21.1 | 326 | 596 | 760804 |
6 AWG (16 mm2) | ||||||
6 | 4 | 1.002 | 25.5 | 494 | 785 | 760604 |
4 AWG (21 mm2) | ||||||
4 | 4 | 1.186 | 30.1 | 648 | 965 | 760404 |
2 AWG (33.7 mm2) | ||||||
2 | 4 | 1.395 | 35.4 | 985 | 1339 | 760204 |