Prysmian and Draka Cable LT 2.0 with Bend Insensitive Fiber Gel Loose Tube Cable
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable 4 to 72 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 156 to 216 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 228 to 264 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 276 to 288 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 290 to 456 Fiber Count All Dielectric Non Armored Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 4 to 72 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 156 to 216 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 228 to 264 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 276 to 288 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 290 to 456 Fiber Count Single Jacket Armored SP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 4 to 72 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 156 to 216 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 228 to 264 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 276 to 288 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 290 to 456 Fiber Count Double Jacket Single Armored PSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 4 to 72 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 156 to 216 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 218 to 264 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 266 to 288 Fiber Count Dielectric Double Jacket PDP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 4 to 72 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 216 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 218 to 264 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 266 to 288 Fiber Count Double Jacket Double Armored SPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 4 to 72 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 146 to 216 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 218 to 264 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
- Prysmian and Draka Cable 266 to 288 Fiber Count Triple Jacket Double Armored PSPSP Bend Insensitive Fiber Gel Loose Tube Cable
Product Details
Overview: A compact, bend-optimized solution for the outside plant, LT 2.0 is a multi-purpose loose tube cable offering up to a 10% to 20% reduction in diameter depending on the design and up to 30% reduction in weight while meeting or exceeding RUS/RDUP and GR20 industry standards. This product platform utilizes bend-insensitive single-mode fiber to deliver superior bending tolerance and cold temperature performance
Applications: Multi-purpose outdoor - aerial lashed, duct, direct buried
Constructions: Dielectric, armored, double armored, dual Jacket (armored designs)
Fiber Count: 4 to 456 fibers in color-coded buffer tubes
Fiber Types: G657.A1 or A2 bend-insensitive single-mode
Options: Dry buffer tubes
Other Versions: Loose tube with 2.5 buffer tubes for indoor, outdoor, indoor-outdoor applications
Performance: ICEA 640, RUS 7 CFR 1755, Telcordia GR-20 and IEC 60794-3-11
Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001
Features and Benefits
Up to 20% Smaller Than Standard Loose Tube Cable
• Counts up to 456 can be placed in a 1-inch duct
• Smaller, less-expensive duct can be used
• Can be placed into occupied ducts
Improved Reel Capacities
• Up to 40% more cable on a reel
• Longer lengths can be installed from the same reel or, smaller, lighter reels can be used
• Saves money on storage & overcomes pay-off limitations
Up to 30% Lighter Than Standard Loose Tube Cable
• Easier to handle during installation
• Less load on aerial structures
• Further reduces total weight (reel + cable)
Smaller Cable Bend Radius
• Easier to install in tight spaces
• Allows use of smaller pedestals and hand-holes
RDUP/RUS PE90 Compliant Cable and Buffer Tube
• Up to 20 feet of tube can be stored in closures
Smaller Buffer Tube Bend Radius
• Flexible 2.0 mm tube is highly kink-resistant
• Can be stored in a 20 mm radius with G657.A2 fiber
• More tube can be stored in a small space
• Allows use of smaller splice trays and closures
Bend-Insensitive Fibe
• ITU G657.A1 fiber is rated for bends down to 10 mm
• ITU G657.A2 fiber is rated for bends down to 7.5 mm
• Fully compliant to G.652.D SSMF specs
Improved Cable Entry and Preparation
• ezPREP® armor greatly improves mid-sheath cable entry
• Dual ripcords speed armored cable entry and outer jacket removal
• Dry core design speeds cable preparation
fiber count | tno of buffer tubes | bend radius load inches (cm) |
bend radius no load inches (cm) |
Action |
All-dielectric (non-armored) Gel tube (e2g1jkt) | ||||
4 to 72 | 6 | 8 (19) | 4 (10) | Request a Quote |
74 to 84 | 7 | 8 (21) | 4 (10) | Request a Quote |
86 to 96 | 8 | 8 (21) | 4 (11) | Request a Quote |
98 to 108 | 9 | 8 (21) | 5 (11) | Request a Quote |
110 to 120 | 10 | 9 (23) | 5 (12) | Request a Quote |
122 to 132 | 11 | 10 (24) | 5 (12) | Request a Quote |
134 to 144 | 12 | 10 (25) | 5 (13) | Request a Quote |
156 to 216 | 18 | 11 (27) | 5 (13) | Request a Quote |
228 to 264 | 22 | 11 (28) | 6 (14) | Request a Quote |
276 to 288 | 24 | 12 (29) | 6 (15) | Request a Quote |
290 to 456 | 38 | 14 (35) | 7 (18) | Request a Quote |
single jacket armored (sp) Gel tube (e2g1a1j) | ||||
4 to 72 | 6 | 9 (22) | 4 (11) | Request a Quote |
74 to 84 | 7 | 9 (24) | 5 (12) | Request a Quote |
86 to 96 | 8 | 10 (24) | 5 (12) | Request a Quote |
98 to 108 | 9 | 10 (26) | 5 (13) | Request a Quote |
110 to 120 | 10 | 11 (28) | 5 (14) | Request a Quote |
122 to 132 | 11 | 11 (29) | 6 (14) | Request a Quote |
134 to 144 | 12 | 12 (30) | 6 (15) | Request a Quote |
156 to 216 | 18 | 12 (30) | 6 (15) | Request a Quote |
228 to 264 | 22 | 13 (33) | 6 (16) | Request a Quote |
276 to 288 | 24 | 14 (35) | 7 (17) | Request a Quote |
290 to 456 | 38 | 15 (39) | 8 (19) | Request a Quote |
double jacket single armored (psp) Gel tube (e2g1a2j) | ||||
4 to 72 | 6 | 10 (25) | 5 (13) | Request a Quote |
74 to 84 | 7 | 10 (26) | 5 (13) | Request a Quote |
86 to 96 | 8 | 10 (27) | 5 (13) | Request a Quote |
98 to 108 | 9 | 11 (28) | 6 (14) | Request a Quote |
110 to 120 | 10 | 12 (30) | 6 (15) | Request a Quote |
122 to 132 | 11 | 12 (31) | 6 (15) | Request a Quote |
134 to 144 | 12 | 12 (32) | 6 (16) | Request a Quote |
156 to 216 | 18 | 13 (32) | 6 (16) | Request a Quote |
228 to 264 | 22 | 14 (35) | 7 (17) | Request a Quote |
276 to 288 | 24 | 14 (36) | 7 (18) | Request a Quote |
290 to 456 | 36 | 16 (42) | 8 (21) | Request a Quote |
dielectric double jacket (pdp) Gel tube (e2gna2j) | ||||
4 to 72 | 6 | 8 (22) | 4 (11) | Request a Quote |
74 to 84 | 7 | 9 (23) | 5 (12) | Request a Quote |
86 to 96 | 8 | 9 (24) | 5 (12) | Request a Quote |
98 to 108 | 9 | 10 (25) | 5 (13) | Request a Quote |
110 to 120 | 10 | 10 (27) | 5 (13) | Request a Quote |
122 to 132 | 11 | 11 (28) | 5 (14) | Request a Quote |
134 to 144 | 12 | 11 (29) | 6 (15) | Request a Quote |
156 to 216 | 18 | 11 (29) | 6 (15) | Request a Quote |
218 to 264 | 22 | 13 (32) | 6 (16) | Request a Quote |
266 to 288 | 24 | 13 (33) | 7 (17) | Request a Quote |
double jacket double armored (spsp) Gel tube (e2g2a2j) | ||||
4 to 72 | 6 | 13 (32) | 6 (16) | Request a Quote |
74 to 84 | 7 | 13 (34) | 7 (17) | Request a Quote |
86 to 96 | 8 | 13 (34) | 7 (17) | Request a Quote |
98 to 108 | 9 | 14 (36) | 7 (18) | Request a Quote |
110 to 120 | 10 | 15 (37) | 7 (19) | Request a Quote |
122 to 132 | 11 | 15 (38) | 8 (19) | Request a Quote |
134 to 144 | 12 | 15 (39) | 8 (20) | Request a Quote |
134 to 216 | 18 | 15 (39) | 8 (20) | Request a Quote |
218 to 264 | 22 | 17 (42) | 8 (21) | Request a Quote |
266 to 288 | 24 | 17 (43) | 9 (22) | Request a Quote |
triple jacket double armored (pspsp) Gel tube (e2g2a3j) | ||||
4 to 72 | 6 | 14 (35) | 7 (17) | Request a Quote |
74 to 84 | 7 | 14 (36) | 7 (18) | Request a Quote |
86 to 96 | 8 | 14 (36) | 7 (18) | Request a Quote |
98 to 108 | 9 | 15 (38) | 7 (19) | Request a Quote |
110 to 120 | 10 | 15 (39) | 8 (20) | Request a Quote |
122 to 132 | 11 | 16 (40) | 8 (20) | Request a Quote |
134 to 144 | 12 | 16 (41) | 8 (21) | Request a Quote |
146 to 216 | 18 | 16 (42) | 8 (21) | Request a Quote |
218 to 264 | 22 | 17 (44) | 9 (22) | Request a Quote |
266 to 288 | 24 | 18 (45) | 9 (23) | Request a Quote |