Service Wire Multi Conductor Zero Halogen Limited Smoke Cable 600 Volt
Select gauge from drop-down menu for prices:
- Service Wire 8 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH8/3
- Service Wire 6 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH6/3
- Service Wire 4 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH4/3
- Service Wire 3 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH3/3
- Service Wire 2 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH2/3
- Service Wire 1 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH1/3
- Service Wire 1/0 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH1/03
- Service Wire 2/0 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH2/03
- Service Wire 3/0 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH3/03
- Service Wire 4/0 AWG 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH4/03
- Service Wire 250 MCM 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH250/3
- Service Wire 350 MCM 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH350/3
- Service Wire 500 MCM 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH500/3
- Service Wire 600 MCM 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH600/3
- Service Wire 750 MCM 3 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH750/3
- Service Wire 8 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH8/4
- Service Wire 6 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH6/4
- Service Wire 4 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH4/4
- Service Wire 3 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH3/4
- Service Wire 2 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH2/4
- Service Wire 1 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH1/4
- Service Wire 1/0 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH1/04
- Service Wire 2/0 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH2/04
- Service Wire 3/0 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH3/04
- Service Wire 4/0 AWG 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH4/04
- Service Wire 250 MCM 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH250/4
- Service Wire 350 MCM 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH350/4
- Service Wire 500 MCM 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH500/4
- Service Wire 600 MCM 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH600/4
- Service Wire 750 MCM 4 Conductors Jacketed MC XHHW-2/EnviroPlus Tested Zero Halogen Limited Smoke 600V Copper Cable AANH750/4
Description:
Limited smoke copper cable is a portable Service cable with a characteristic limited smoke MC XHHW-2 jacket. The cable has excellent flame-retardant property that primarily defines it. Its cross-linked polythene insulator has good heat resistant. This type of cable is therefore suitable for applications in hazardous locations and punishing environments because of this tough, robust and flame retardant insulation and jacket.
Application:
Limited smoke copper cable is suitable for use in hazardous locations because of its tough MC XHHW-2 jacket. It can serve well in both wet and dry locations because its tough jacket can resist moisture, water and UV rays. Applications involving direct burial can be circuited using this cable because of its wide temperature range that can withstand the varying temperatures below the ground.
Conductor:
• stranded copper conductor
• 3 or 4 phase conductors made from stranded copper.
• Single ground wire; bare copper
• Phase cabling with fillers
Insulation:
• Type XHHW-2 crosslinked polyethylene material.
Jacket:
• MC XHHW-2 jacket, also known as EnviroPlus
Features:
• 90°C temperature rating in both wet and dry locations
• Rated at -40°C for cold temperatures
• Excellent sunlight resistance
• Suitable for direct burial
• Two-firewall
• Zero halogen jacket
Standards:
• NEMA WC-70
• UL 1569
• ICEA S-95-658
• IEEE 383 Flame test, 70000 BTU
• IEEE 1202
• UL 15581
• UL 1685
• CSA FT-4
• Hazardous location standards; class 1 – div 2, and Div. 2 of Class 2
• RoHS compliant