Belden 20 AWG 1 Triad 300V PLTC Beldfoil Shielding Cable

Belden 20 AWG 1 Triad 300V PLTC Beldfoil Shielding Cable

Select gauge from drop-down menu for prices:

Belden 20 AWG 1 Triad 300V PLTC Beldfoil Shielding Cable

Precio habitual $3.95 $2.63 Oferta /per Foot

Belden 20 AWG 1 Triad 300V PLTC Beldfoil Shielding Cable

Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC - Polyvinyl Chloride
• Dia. (mm): 1.7272

Outer Shield Drian Wire AWG:
• AWG: 22
• Stranding: 19x34
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 46.134 Kg/Km
• Max. Recommended Pulling Tension: 204.617 N
• Min. Bend Radius/Minor Axis: 57.150 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.62339
• Nom. Capacitance Conductor to Shield (pF/m): 180.455
• Nom. Capacitance Conductor to Conductor (pF/m): 98.43
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 31.1695
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 21.3265
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4.8 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads overall cable-
nominal dia. (mm)
belden cable
part number
Action
20 1 5.664 9364 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question