Belden Cable Overall Foil/Braid Shield Low Capacitance Computer Cables for EIA RS-232 Applications Multi Conductor Paired Cable

Belden Cable Overall Foil/Braid Shield Low Capacitance Computer Cables for EIA RS-232 Applications Multi Conductor Paired Cable

Select gauge from drop-down menu for prices:

Belden Cable Overall Foil/Braid Shield Low Capacitance Computer Cables for EIA RS-232 Applications Multi Conductor Paired Cable

Product Details

Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.

Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.

Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.2794

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 33 lbs/1000 ft.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• CSA Specification: AWM I A
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 75
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 50
• Nominal Velocity of Propagation (VP %): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 24
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 5.4
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.8 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
24 2 6.350 8332 Request A Quote
24 3 6.731 8333 Request A Quote
24 4 6.909 8334 Request A Quote
24 5 7.493 8335 Request A Quote
24 6 7.874 8336 Request A Quote
24 7 8.153 8337 Request A Quote
24 10 9.779 8340 Request A Quote
24 12 10.338 8342 Request A Quote
24 15 11.303 8345 Request A Quote
24 18 12.192 8348 Request A Quote
24 25 13.970 8355 Request A Quote
22 2 7.112 8302 Request A Quote
22 3 7.468 8303 Request A Quote
22 4 8.128 8304 Request A Quote
22 5 8.179 8305 Request A Quote
22 6 8.839 8306 Request A Quote
22 7 8.839 8307 Request A Quote
22 8 9.754 8308 Request A Quote
22 10 11.176 8310 Request A Quote
22 12 11.557 8312 Request A Quote
22 15 12.751 8315 Request A Quote
22 18 13.716 8318 Request A Quote
22 25 15.748 8325 Request A Quote