Belden Thermocouple Extension Overall Beldfoil Shielding Solid Conductor Cable

Belden Thermocouple Extension Overall Beldfoil Shielding Solid Conductor Cable

Product Details

Connect your devices to sensing or controlling equipment with thermocouple wire and extension grade cable from Belden.

With products designed for compliance to American National Standards Institute (ANSI) and IEC standards, Belden has the right solution for your needs.

Benefits:
• Generates measurable electrical energy with dissimilar conductors
• Enhanced performance in high operating temperature environments
• Color coded insulation and jacket materials for easy identification

Features:
• Meets ANSI/IEC Type E/J/K/T/EX/JX/KX/TX standards
• Multiple alloy options for measuring electrical readings
• Additional constructions available upon request

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.533
• Dia. (mm): 1.880

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Pair Lay Length and Direction:
• Lay Length (mm): 50.8
• Twists (twist/m): 19.686

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 38.693 Kg/Km
• Max. Recommended Pulling Tension: 128.998 N
• Min. Bend Radius/Minor Axis: 53.340 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• CSA Specification: FT4
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 1202
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• ANSI Specification: MC 96.1-1982 Type JX

Surface Printing (Overall):
Electrical Characteristics (Overall):
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 34.7786

Flame Test:
• UL Flame Test: UL1685 FT4 Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal dia. (mm)
belden cable
part number
Action
20 1 5.740 3111A Request A Quote
20 1 5.740 3112A Request A Quote
20 1 5.740 3113A Request A Quote
16 1 6.706 1101A Request A Quote
16 1 6.706 1000A Request A Quote
16 1 6.706 1018A Request A Quote
16 1 6.706 1023A Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question