Belden Thermocouple Extension Overall Beldfoil Shielding Solid Conductor Cable
Select gauge from drop-down menu for prices:
- Belden 3111A 20 AWG 1 Pair JX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 3112A 20 AWG 1 Pair KX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 3113A 20 AWG 1 Pair TX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 1101A 16 AWG 1 Pair EX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 1000A 16 AWG 1 Pair JX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 1018A 16 AWG 1 Pair KX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
- Belden 1023A 16 AWG 1 Pair TX ANSI Type Thermocouple Extension Multi Conductor Solid Cable
Product Details
Connect your devices to sensing or controlling equipment with thermocouple wire and extension grade cable from Belden.
With products designed for compliance to American National Standards Institute (ANSI) and IEC standards, Belden has the right solution for your needs.
Benefits:
• Generates measurable electrical energy with dissimilar conductors
• Enhanced performance in high operating temperature environments
• Color coded insulation and jacket materials for easy identification
Features:
• Meets ANSI/IEC Type E/J/K/T/EX/JX/KX/TX standards
• Multiple alloy options for measuring electrical readings
• Additional constructions available upon request
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.533
• Dia. (mm): 1.880
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
Pair Lay Length and Direction:
• Lay Length (mm): 50.8
• Twists (twist/m): 19.686
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 38.693 Kg/Km
• Max. Recommended Pulling Tension: 128.998 N
• Min. Bend Radius/Minor Axis: 53.340 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• CSA Specification: FT4
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 1202
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• ANSI Specification: MC 96.1-1982 Type JX
Surface Printing (Overall):
Electrical Characteristics (Overall):
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 34.7786
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
20 | 1 | 5.740 | 3111A | Request A Quote |
20 | 1 | 5.740 | 3112A | Request A Quote |
20 | 1 | 5.740 | 3113A | Request A Quote |
16 | 1 | 6.706 | 1101A | Request A Quote |
16 | 1 | 6.706 | 1000A | Request A Quote |
16 | 1 | 6.706 | 1018A | Request A Quote |
16 | 1 | 6.706 | 1023A | Request A Quote |