General Cable HVTECK® 3C 320 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA

General Cable HVTECK® 3C 320 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 25kV CSA

Product Details

Conductor: 1 AWG thru 350 kcmil bare copper compact Class B strand

Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor

Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)

Insulation Shield:
• This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
• Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Aluminum Interlocked Armor (AIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black or as requested

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For wiring in all hazardous locations when used with certified HL cable glands
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)

Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 131 and No. 174
• CSA Standard C68.10

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
• ICEA T-29-520 (210,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

cond. size
(awg/ kcmil)
no. of cond. outdoor amp**
(40?c ambient)
general cable
part number
Action
1 3 164 17496.860100* Request A Quote
1/0 3 187 17496.865100* Request A Quote
2/0 3 215 17496.865200* Request A Quote
3/0 3 245 17496.865300* Request A Quote
4/0 3 281 17496.865400* Request A Quote
250 3 310 17496.866000* Request A Quote
350 3 377 17496.866200* Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question