Belden 14 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable
Select gauge from drop-down menu for prices:
Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.
No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon
Outer Shield Drain Wire AWG:
• AWG: 16
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.176
• Outer Jacket Ripcord: Yes
Pair Lay Length and Direction:
• Lay Length (in.): 3.750
• Twists (twist/ft): 3.200
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 81 lbs/1000 ft.
• Max. Recommended Pulling Tension: 160 lbs.
• Min. Bend Radius/Minor Axis: 3.300 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402
Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft): 48
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/ft): 102
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.3
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.4
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 10 Amps/conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
14 | 1 | 8.382 | 3080A | Request A Quote |