General Cable Duralox® XLPE AIA PVC (1/0 AWG-1000MCM) Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
Select gauge from drop-down menu for prices:
- General Cable Duralox® XLPE AIA PVC 1/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 2/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 3/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 4/0 AWG 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 250MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 350MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 500MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 750MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
- General Cable Duralox® XLPE AIA PVC 1000MCM 3 Conductors Type MC 3C Power Armored with Enhanced Ground Wires (50%) 600V UL
Product Details
Conductors: 1/0 AWG thru 1000 kcmil bare compact copper, Class B stranding per ASTM B496
Insulation:
• Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 3, Table E-2
Ground: Annealed bare copper Class B stranding per ASTM B8
Armor: Aluminum Interlocked Armor (AIA)
Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• Ideally suited for use in a broad range of commercial, industrial and utility applications, where maximum performance is demanded, ease of installation desired and fire resistance is critical
• Permitted for use per NEC Article 334 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2
• Installed in both exposed or concealed work, wet or dry locations, indoors or outdoors and cable trays
Features:
• Rated at 90?C wet or dry
• Provides excellent oil and chemical resistance
• Excellent crush resistance
• Provides a long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend test at -40?C
Compliances:
Industry Compliances:
• UL 1569
• UL 44
• ICEA S-95-658/NEMA WC70
• UL Type MC-600 volts, UL File # E90496
• NEC Type XHHW-2 conductors
Flame Test Compliances:
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging: For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
cond. size (awg) |
no. of cond. |
general cable part number |
service wire part number |
Action |
1/0 | 3 | 11298.515100* | AAP1/03G3#6 | Request A Quote |
2/0 | 3 | 11298.515200* | AAP2/03G3#6 | Request A Quote |
3/0 | 3 | 11298.515300* | AAP3/03G3#4 | Request A Quote |
4/0 | 3 | 11298.515400* | AAP4/03G3#4 | Request A Quote |
250 | 3 | 11298.516000* | AAP250/3G3#4 | Request A Quote |
350 | 3 | 11298.516200* | AAP350/3G3#2 | Request A Quote |
500 | 3 | 11298.516500 | AAP500/3G3#1 | Request A Quote |
750 | 3 | 11298.517000* | AAP750/3G3#2/0 | Request A Quote |
1000 | 3 | 17604 | 11298.517500* | Request A Quote |