Belden 18 AWG 300V PLTC Individually and Overall Beldfoil Shield Triads Orange Communication Cable
Select gauge from drop-down menu for prices:
Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.
No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Insulation:
• Material: PVC - Polyvinyl Chloride
Communication Wire:
• AWG: 22
• Material: BC - Bare Copper
• Stranding: 7x30
Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape
Inner Shield Drian Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Shield Drian Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.397
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 110 lbs/1000 ft.
• Max. Recommended Pulling Tension: 175 lbs.
• Min. Bend Radius/Minor Axis: 4.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: PLTC, ITC, CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.17
• Nom. Capacitance Conductor to Conductor (pF/ft): 54
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/ft): 101
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86 (18 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 14.7 (22 AWG)
• Nom. Inner Shield DC Resistance @ 20°C (Ohm/1000 ft): 10.3
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.9
• Max. Operating Voltage - UL: 300 V RMS
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
• ICEA Flame Test: T-29-520
Suitability:
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # triads | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
18 | 2 | 11.430 | 3028A | Request A Quote |
18 | 4 | 13.538 | 3031A | Request A Quote |
18 | 8 | 17.755 | 3033A | Request A Quote |
18 | 12 | 21.336 | 3068A | Request A Quote |
18 | 16 | 24.740 | 3037A | Request A Quote |
18 | 24 | 30.480 | 3039A | Request A Quote |