Belden 14 and 10 AWG Interlocked Armor Composite Uninsulated Ground Wire UL Control 600V Type MC Metal Clad Cable
Select gauge from drop-down menu for prices:
Product Details
Combine rugged durability and corrosion resistance with flexibility and easy handling by choosing Type MC Metal Clad cable from Belden.
With aluminum interlocking armor, you eliminate the need for costly conduit or burial piping with cables designed to meet the needs of demanding industrial and resource industry environments.
Benefits:
• Eliminate the use of costly conduit or burial piping
• Benefit from superior performance in wet electrical and extreme temperature environments — indoors or outdoors
• Assure your connections with stranded conductors that terminate easily and safely
Features:
• Request standard aluminum interlock armor or galvanized steel armor as added safeguards (14-2AWG)
• Protect outdoor uses — rated for sunlight-resistance, installation in cable trays and direct burial
• Install with confidence in Class I and II Div. 2 and Class III Div. 1 and 2 hazardous locations
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 10
• Ground Wire Stranding: 7x18
• Ground Wire Conductor Material: BC - Bare Copper
Insulation:
• Material: XLPE - Cross Linked Polyethylene
• Wall Thickness (mm): 0.762
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.27
• Outer Jacket over Armor (y/n): Y
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.74
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 602.721 Kg/Km
• Max. Recommended Pulling Tension: 1356.700 N
• Min. Bend Radius/Minor Axis: 259.080 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: MC, XHHW-2 Singles, UL1569
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/13/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 3.34662 (10 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 8.5306 (14 AWG)
• Max. Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 12 Amps/conductor @ 25°C (14 AWG)
• Max. Recommended Current: 24 Amps/conductor @ 25°C (10 AWG)
Flame Test:
• UL Flame Test: VW-1 Singles, UL1685 UL Loading
Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | belden cable part number |
Action | ||
al. | steel | aluminum | steel | ||
14 and 10 | 14 and 10 | 6 | 27429 | 28429 | Request A Quote |