Lapp OLFLEX® VFD with Signal Flexible 600V UL TC-ER Approved Cable

Lapp OLFLEX® VFD with Signal Flexible 600V UL TC-ER Approved Cable

ÖLFLEX® VFD with Signal is an extremely oil- and UV-resistant shielded motor power cable for VFD drives, with an additional pair for brake or temperature sensor. It is designed with LAPP Surge Guard insulation, which includes a semiconductive layer made to withstand nonlinear power distortions associated with VFD drives and to disperse increases in voltage. It is resistant to a wide range of disinfecting solutions used in the food, beverage, chemical and related industries.

Construction
Conductors:
• Finely stranded bare copper
Insulation:
• LAPP Surge Guard insulation system
Shielding:
• barrier tape triple layer foil tape (100% coverage)tinned copper braid (85% coverage)
Jacket:
• specially formulated thermoplastic polymer black
Technical data
Minimum bend radius:
• 7.5 x cable diameter
Temperature range:
• - UL/CSA TC: -25°C to +90°C
• - for stationary use: -40°C to +105°C
• - for flexible use: -25°C to +105°C
Nominal voltage:
• - UL/CSA TC: 600V
• - UL WTTC: 1000V
• - UL Flexible Motor Supply: 1000V
• - UL/CSA AWM: 1000V
Test voltage:
• 2000V
Peak voltage:
• 7500V
Conductor stranding:
• - 16-6 AWG: Class 5 fine wire
• - 4 AWG: Class K fine wire
Color code:
• black with white numbers,plus green/yellow ground and one black pair with white numbers
Approvals:
• UL: UL: TC-ER per UL 1277
MTW per UL 1063
WTTC per UL 2277
AWM 20886
• Attributes: UL Oil Res I/II
75°C wet; 90°C dry
-40°C cold bend; -25°C cold impact
sunlight resistant
direct burial
NFPA 79
• NEC: Class 1 Division 2 per NEC Article 501
• Canada: c(UL) CIC/TC FT4
CSA AWM I/II A/B 1000V FT4
• Additional: CMSHA P-07-KA050011-MSHA
CE & RoHS
Features
• LAPP Surge Guard insulation system
• UL TC-ER & c(UL) CIC TC approved
• Double-shielded for extra protection.
• Contains pair for brake or temperature sensor
• Resistant to a wide range of disinfecting solutions used in the food, beverage, chemical and related industries,according to ECOLAB® PM 40-1 test procedure

AWG Number of conductors Nominal Outer
Diameter
Copper Weight
(lbs/mft)
Approx. Weight
(lbs/mft)
Part Number
inches mm
16 AWG (1.5 mm²)
16 4 + (18 AWG) 0.519 13.2 88 180 7416048
14 AWG (2.5 mm²)
14 4 + (18 AWG) 0.573 14.6 118 216 7414048
14 4 + (14 AWG) 0.600 15.2 141 254 7414044
12 AWG (4 mm²)
12 4 + (18 AWG) 0.632 16.1 162 286 7412048
12 4 + (14 AWG) 0.662 16.8 187 326 7412044
10 AWG (6 mm²)
10 4 + (14 AWG) 0.745 18.9 260 406 7410044
8 AWG (10 mm²)
8 4 + (14 AWG) 0.896 22.8 375 617 7408044
6 AWG (16 mm²)
6 4 + (14 AWG) 1.026 26.1 472 848 7406044
4 AWG (24 mm²)
4 4 + (14 AWG) 1.324 33.6 643 1251 7404044

( ) = shielded pair