Belden Cable Basics Symmetrical Design Dual Copper Tape VFD Cable
Select gauge from drop-down menu for prices:
- Belden 29520C Cable 16 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29521C Cable 14 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29522C Cable 12 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29523C Cable 10 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29524C Cable 8 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29525C Cable 6 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29526C Cable 4 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29527C Cable 2 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden Cable 1 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable 29528C
- Belden 29529C Cable 1/0 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29530C Cable 2/0 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29531C Cable 3/0 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
- Belden 29532C Cable 4/0 AWG 3 Conductors Basics Symmetrical Design Dual Copper Tape VFD Cable
Product Details
Classic Symmetrical Designs Features:
• Available with high-strand conductors in large AWG sizes
• Design features a copper tape shield with segmented ground
• Smaller OD than the Classic Designs with Foil/Braid
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 100% ground three conductor
• Shielding: Dual Copper Tape
• Grounding: Bare 3x Segmented
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Bare Copper
• Rating: 600V UL TC-ER
• 1000V CSA AWM I/II A/B FT4
• IEEE 1202
• UL Direct Burial
• XHHW-2, RHW-2 rated circuit conductors
• 90°C Wet/Dry
• Suitable for Class I, II & III, Division 2 hazardous locations
• UL 1685 Vertical Tray Flame Test
• RoHS compliant
• CE approved
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
awg |
cond. stranding |
minimum bend radius |
belden cable part number |
Action | |
inch | mm | ||||
16 | 7 x 24 | 4.0 | 101.6 | 29520C | Request A Quote |
14 | 7 x 22 | 4.3 | 108.0 | 29521C | Request A Quote |
12 | 7 x 20 | 4.6 | 116.8 | 29522C | Request A Quote |
10 | 7 x 18 | 5.1 | 129.5 | 29523C | Request A Quote |
8 | 7 x 16 | 6.5 | 165.1 | 29524C | Request A Quote |
6 | 7 x 14 | 7.3 | 185.4 | 29525C | Request A Quote |
4 | 7 x 12 | 8.3 | 209.6 | 29526C | Request A Quote |
2 | 7 x 10 | 10.0 | 254.0 | 29527C | Request A Quote |
1 | 19 x 14 | 11.5 | 292.1 | 29528C | Request A Quote |
1/0 | 19 x 13 | 12.3 | 311.1 | 29529C | Request A Quote |
2/0 | 19 x 12 | 13.3 | 336.6 | 29530C | Request A Quote |
3/0 | 19 x 11 | 14.3 | 362.0 | 29531C | Request A Quote |